Suppr超能文献

[A study on the role of the dispersion of repolarization in the induction of ventricular fibrillation using the suction electrode technique].

作者信息

Gotoh M

出版信息

Nihon Ika Daigaku Zasshi. 1989 Aug;56(4):349-60. doi: 10.1272/jnms1923.56.349.

Abstract

The arrhythmogenic role of increased dispersion of repolarization (Dispersion) in monophasic action potentials (MAPs) was studied in 12 open-chest dogs. Following exposure of the heart by pericardial cradle, four MAPs were recorded simultaneously from the right and left ventricular surfaces using the suction electrode technique. Maximum dispersion (maxDIS) was defined as the greatest Dispersion between any two of the four MAPs in atrial pacing and ventricular premature stimulation (VPS). Dispersion was increased by warming the heart with a heat lamp and regional cooling with a cold saline (2-4 degrees C) drip. In control experiments maxDIS in atrial pacing (PCL: 500 ms) was 21 +/- 10 ms. MaxDIS was increased when the VPS was applied at the right ventricular apex (RVa) (maxDIS: 73 +/- 17 ms), at the left ventricular base (LVb) (maxDIS: 78 +/- 34 ms), and at the left ventricular apex (LVa) (maxDIS: 89 +/- 20 ms). Ventricular fibrillation, however was not induced by any VPSs. Warming the heart and regional cooling increased Dispersion from the control value to 180 +/- 58 ms (p less than 0.001), mainly because of the increased MAP duration difference (delta MAPD) in atrial pacing, but no ventricular fibrillation occurred spontaneously. VPS applied at the LVa induced ventricular fibrillation following marked increase of maxDIS, which was due to added contributions of delta MAPD and the maximal difference between activation times (delta AT). With RVb cooling ventricular fibrillation was induced in 16/20 cases (80%) (maxDIS: 286 +/- 124 ms), with RVa cooling in 6/9 cases (67%) (maxDIS: 263 +/- 109 ms), and with LVb cooling in 11/23 cases (48%) (maxDIS: 172 +/- 67 ms). There was significant linear correlation between maxDIS and delta AT (r = 0.88, p less than 0.01), and also delta MAPD (r = 0.80, p less than 0.01). We conclude that the increased Dispersion plays an important role in the induction of ventricular fibrillation. This temperature gradient model is a favorable tool to study the role of Dispersion as one of the important factors which induce ventricular fibrillation.

摘要

相似文献

3
Mechanism of ventricular arrhythmias caused by increased dispersion of repolarization.
Eur Heart J. 1985 Nov;6 Suppl D:63-70. doi: 10.1093/eurheartj/6.suppl_d.63.
8
The JT-area indicates dispersion of repolarization in dogs with atrioventricular block.
J Interv Card Electrophysiol. 2002 Jun;6(2):113-20. doi: 10.1023/a:1015302415323.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验