• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The "collimator monitoring fill factor" of a two-dimensional detector array, a measure of its ability to detect collimation errors.

作者信息

Stelljes Tenzin Sonam, Looe Hui Khee, Harder Dietrich, Poppe Björn

机构信息

University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University Oldenburg, Germany.

Prof. em., Medical Physics and Biophysics, Georg-August-University, Göttingen, Germany.

出版信息

Med Phys. 2017 Mar;44(3):1128-1138. doi: 10.1002/mp.12106.

DOI:10.1002/mp.12106
PMID:28094849
Abstract

PURPOSE

Two-dimensional detector arrays are routinely used for constancy checks and treatment plan verification in photon-beam radiotherapy. In addition to the spatial resolution of the dose profiles, the "coverage" of the radiation field with respect to the detection of any beam collimation deficiency appears as the second characteristic feature of a detector array. The here proposed "collimator monitoring fill factor" (CM fill factor) has been conceived to serve as a quantitative characteristic of this "coverage".

METHODS

The CM fill factor is defined as the probability of a 2D array to detect any collimator position error. Therefore, it is represented by the ratio of the "sensitive area" of a single detector, in which collimator position errors are detectable, and the geometrical "cell area" associated with this detector within the array. Numerical values of the CM fill factor have been Monte Carlo simulated for 2D detector arrays equipped with air-vented ionization chambers, liquid-filled ionization chambers and diode detectors and were compared with the "FWHM fill factor" defined by Gago-Arias et al. (2012).

RESULTS

For arrays with vented ionization chambers, the differences between the CM fill factor and the FWHM fill factor are moderate, but occasionally the latter exceeds unity. For narrower detectors such as liquid-filled ionization chambers and Si diodes and for small sampling distances, large differences between the FWHM fill factor and the CM fill factor have been observed. These differences can be explained by the shapes of the fluence response functions of these narrow detectors.

CONCLUSIONS

A new parameter "collimator monitoring fill factor" (CM fill factor), applicable to quantitate the collimator position error detection probability of a 2D detector array, has been proposed. It is designed as a help in classifying the clinical performance of two-dimensional detector arrays in photon-beam radiotherapy.

摘要

相似文献

1
The "collimator monitoring fill factor" of a two-dimensional detector array, a measure of its ability to detect collimation errors.
Med Phys. 2017 Mar;44(3):1128-1138. doi: 10.1002/mp.12106.
2
Experimental determination of the "collimator monitoring fill factor" and its relation to the error detection capabilities of various 2D-arrays.实验确定“准直器监测填充因子”及其与各种 2D 阵列的误差检测能力的关系。
Med Phys. 2019 Apr;46(4):1863-1873. doi: 10.1002/mp.13417. Epub 2019 Feb 18.
3
Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.6兆伏放射治疗光子束中九个小场探测器的输出校正因子:一项PENELOPE蒙特卡罗研究
Med Phys. 2014 Apr;41(4):041711. doi: 10.1118/1.4868695.
4
Experimental determination of the lateral dose response functions of detectors to be applied in the measurement of narrow photon-beam dose profiles.用于窄光子束剂量分布测量的探测器横向剂量响应函数的实验测定。
Phys Med Biol. 2015 Dec 21;60(24):9421-36. doi: 10.1088/0031-9155/60/24/9421. Epub 2015 Nov 19.
5
Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.用于先进放射治疗技术质量保证的像素间距为3.5毫米的电离室阵列的研制与临床评估
Med Phys. 2016 May;43(5):2283. doi: 10.1118/1.4945414.
6
Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.用于放射治疗中治疗验证的二维充液电离室探测器阵列的特性描述。
Med Phys. 2014 May;41(5):051704. doi: 10.1118/1.4870439.
7
Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.探测器间校正:针对小型放射治疗射束输出测量的探测器特定校正因子的全面实验研究。
Med Phys. 2014 Jul;41(7):072103. doi: 10.1118/1.4883795.
8
A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512.用于立体定向放射治疗质量保证的二维硅探测器阵列:MagicPlate - 512
Med Phys. 2014 Sep;41(9):091707. doi: 10.1118/1.4892384.
9
A silicon strip detector array for energy verification and quality assurance in heavy ion therapy.用于重离子治疗中的能量验证和质量保证的硅条探测器阵列。
Med Phys. 2018 Feb;45(2):953-962. doi: 10.1002/mp.12736. Epub 2018 Jan 16.
10
An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets.用于窄不规则调强放疗子野参考剂量测定的微型电离室的 EGSnrc 蒙特卡罗研究
Med Phys. 2004 Sep;31(9):2416-22. doi: 10.1118/1.1767691.