A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL) to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA), uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0-0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children's needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.