Sadeghi Morteza, Ghasemi Gholam Ali, Karimi Mohammad Taghi
Department of Sport Injuries and Corrective Exercise, Faculty of Sports Sciences, University of Isfahan, Isfahan, Iran.
Muscoloskeletal Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
Technol Health Care. 2017;25(3):591-597. doi: 10.3233/THC-171295.
Subjects with Spinal Cord Injury (SCI) should use various assistive devices to stand and walk. Unfortunately they suffer from slow walking speed, high energy consumption, and too much force applied on upper limb while walking. The aim of this study was to determine the gap between the gait performance of SCI and normal subjects to conclude how the performance of SCI can be improved.
Three groups of SCI walked with orthosis, SCI walked without orthosis, and normal subjects were recruited in this study. The normal subjects also walked with the same orthoses as SCI subjects. Some parameters such as ranges of motion of hip, knee and spatiotemporal gait parameters were evaluated by use of Qualysis motion analysis system. The difference between the gait parameters of three groups were evaluated by use of two sample t test.
The mean values of hip joint range of motion of normal subjects while walking with and without orthosis were 48.3 ± 2.5 and 18.5 ± 8.8 degrees, respectively (p-value = 0.00). There was a significant difference between walking speed of normal subjects with and without orthosis. The walking speed of SCI subject with and without orthosis differed significantly.
Although use of orthosis enable SCI subjects to stand and walk, but has some restrictions. As use of orthosis decreased the abilities of normal subjects it can be concluded that more attention should be done on design of orthosis and style of walking.
脊髓损伤(SCI)患者需要使用各种辅助装置来站立和行走。不幸的是,他们行走速度缓慢,能量消耗高,且行走时上肢用力过大。本研究的目的是确定脊髓损伤患者与正常受试者步态表现之间的差距,以得出如何改善脊髓损伤患者的表现。
本研究招募了三组受试者,分别是佩戴矫形器行走的脊髓损伤患者、不佩戴矫形器行走的脊髓损伤患者以及正常受试者。正常受试者也佩戴与脊髓损伤患者相同的矫形器行走。使用Qualysis运动分析系统评估了一些参数,如髋关节、膝关节的活动范围以及时空步态参数。使用两样本t检验评估三组步态参数之间的差异。
正常受试者佩戴和不佩戴矫形器行走时髋关节活动范围的平均值分别为48.3±2.5度和18.5±8.8度(p值=0.00)。正常受试者佩戴和不佩戴矫形器时的行走速度存在显著差异。脊髓损伤患者佩戴和不佩戴矫形器时的行走速度也有显著差异。
虽然使用矫形器能使脊髓损伤患者站立和行走,但存在一些限制。由于使用矫形器降低了正常受试者的能力,因此可以得出结论,应更加关注矫形器的设计和行走方式。