Suppr超能文献

[基于光学相干断层扫描的泪液半月皱襞测量法在泪器病学中的应用]

[Use of optical coherence tomography based lacrimal meniscometry in dacryology].

作者信息

At'kova E L, Yartsev V D, Krakhovetskiy N N, Root A O, Reyn D A

机构信息

Research Institute of Eye Diseases, 11 A, B Rossolimo St., Moscow, 119021, Russian Federation.

出版信息

Vestn Oftalmol. 2016;132(6):101-107. doi: 10.17116/oftalma20161326101-107.

Abstract

UNLABELLED

Optical coherence tomography (OCT) based lacrimal meniscometry is currently the most accurate method used to determine dimensions of tear meniscus. According to related literature, the latter gets reliably reduced after treatment of nasolacrimal duct obstructions. However, the relationship between morphometric parameters of tear meniscus and the intensity of epiphora has not been established. Even an adequate study parameter has not been yet identified.

AIM

To investigate the significance of OCT based lacrimal meniscometry in determining the extent of insufficiency of lacrimal drainage.

MATERIAL AND METHODS

A total of 108 measurements of the lower tear meniscus were taken. Of them, 23 measurements were taken in healthy volunteers, who had no complaints of epiphora, 59 - in patients with epiphora of different intensity, and 26 - in patients after surgical intervention. Meniscometry was performed with RTVue-100-2 (Optovue, USA) optical coherence tomograph. The tear meniscus 'height', 'depth', and coefficient were evaluated. Munk's scores for epiphora were also collected. Spearman's correlation was applied to assess the morphometry results and Munk's scores. A separate analysis was performed for patients who were examined before and after dacryological treatment. Differences were evaluated with the Kruskal-Wallis H test.

RESULTS

Statistically reliable differences were found between the meniscus 'height' and 'depth' values at different epiphora intensities (p<0.001 for both parameters; H=25.35 and 22.01, respectively), however, the meniscus coefficients showed no significant difference in these patients (p=0.8, H=1.57). Moreover, there was a highly reliable (p<0.001) medium strength direct correlation between the meniscus 'height' and 'depth' and the Munk's scores (R=0.46 and R=0,48, respectively), while the correlation between the meniscus coefficient and the Munk's scores appeared weak and lowly reliable (p=0.20, R=0.14).

CONCLUSION

Lower meniscus morphometry with 'depth' measurement is a comprehensive method to assess the state of lacrimal drainage system. However, it should not be used alone due to significant variations in morphometric parameters, particularly in patients with intensive epiphora.

摘要

未标注

基于光学相干断层扫描(OCT)的泪液半月皱襞测量法是目前用于确定泪液半月皱襞尺寸的最准确方法。根据相关文献,在鼻泪管阻塞治疗后,泪液半月皱襞尺寸会可靠地减小。然而,泪液半月皱襞的形态学参数与溢泪强度之间的关系尚未确立。甚至尚未确定一个合适的研究参数。

目的

探讨基于OCT的泪液半月皱襞测量法在确定泪液引流不足程度方面的意义。

材料与方法

共对下泪液半月皱襞进行了108次测量。其中,在无溢泪主诉的健康志愿者中进行了23次测量,在不同溢泪强度的患者中进行了59次测量,在手术干预后的患者中进行了26次测量。使用RTVue - 100 - 2(美国Optovue公司)光学相干断层扫描仪进行半月皱襞测量。评估了泪液半月皱襞的“高度”“深度”和系数。还收集了溢泪的蒙克评分。应用斯皮尔曼相关性分析来评估形态学测量结果与蒙克评分之间的关系。对泪道治疗前后检查的患者进行了单独分析。采用Kruskal - Wallis H检验评估差异。

结果

在不同溢泪强度下,半月皱襞的“高度”和“深度”值存在统计学上的可靠差异(两个参数的p均<0.001;H分别为25.35和22.01),然而,这些患者的半月皱襞系数无显著差异(p = 0.8,H = 1.57)。此外,半月皱襞的“高度”和“深度”与蒙克评分之间存在高度可靠(p<0.001)的中等强度直接相关性(R分别为0.46和0.48),而半月皱襞系数与蒙克评分之间的相关性较弱且可靠性较低(p = 0.20,R = 0.14)。

结论

通过测量“深度”进行下半月皱襞形态学测量是评估泪液引流系统状态的一种综合方法。然而,由于形态学参数存在显著差异,尤其是在溢泪严重的患者中,不应单独使用该方法。