The aim of this study was to compare the Push Ortho Thumb Brace CMC and a custom-made orthosis in the treatment of patients with primary osteoarthritis of the carpometacarpal joint of the thumb. Our outcome measures were pain scores, tests of hand function, patient satisfaction and patient preference.
A multicentre crossover randomised controlled trial was conducted which included 63 patients (44 women) with primary osteoarthritis of the carpometacarpal joint of the thumb. Of these, 59 patients with a mean age of 60.1 years (standard deviation 8.2), completed the study. Patients used both orthoses for two weeks with a two-week washout period in-between. Pain was measured on a 10-cm visual analogue scale. Hand function was assessed using the Jebsen Taylor Hand Function test, Nine Hole Peg Test, key grip, pinch grip and Functional Index for Hand Osteoarthritis. Patient preference was assessed using the Dutch version of the Quebec User Evaluation of Satisfaction with Assistive Technology score.
Both orthoses resulted in a minor reduction in pain scores without significant difference between the two orthoses. The Push Ortho Thumb Brace CMC interfered less with key grip (p < 0.001) and the Nine Hole Peg Test (p < 0.001) than the custom-made orthosis. The Push Ortho Thumb Brace CMC had a higher patient satisfaction (p < 0.001) and most patients preferred this orthosis for future use.
When considering an orthosis for osteoarthritis of the carpometacarpal joint of the thumb, patients may prefer the Push Ortho Thumb Brace CMC. Cite this article: Bone Joint J 2017;99-B:237-44.
本研究旨在比较拇指腕掌关节原发性骨关节炎患者使用推式拇指矫形器CMC和定制矫形器的治疗效果。我们的观察指标包括疼痛评分、手功能测试、患者满意度和患者偏好。
进行了一项多中心交叉随机对照试验,纳入63例(44例女性)拇指腕掌关节原发性骨关节炎患者。其中,59例平均年龄为60.1岁(标准差8.2)的患者完成了研究。患者使用两种矫形器各两周,中间有两周的洗脱期。疼痛采用10厘米视觉模拟量表进行测量。手功能通过Jebsen Taylor手功能测试、九孔插针测试、钥匙握力、捏力和手部骨关节炎功能指数进行评估。患者偏好采用荷兰版魁北克辅助技术满意度评估量表进行评估。
两种矫形器均使疼痛评分略有降低,两者之间无显著差异。与定制矫形器相比,推式拇指矫形器CMC对钥匙握力(p < 0.001)和九孔插针测试(p < 0.001)的干扰较小。推式拇指矫形器CMC的患者满意度更高(p < 0.001),大多数患者更倾向于在未来使用这种矫形器。
在考虑为拇指腕掌关节骨关节炎患者使用矫形器时,患者可能更喜欢推式拇指矫形器CMC。引用本文:《骨与关节杂志》2017年;99-B:237 - 44。