Suppr超能文献

Inter-observer variability between radiologists reporting on cerebellopontine angle tumours on magnetic resonance imaging.

作者信息

Teh S R, Ranguis S, Fagan P

机构信息

University of New South Wales,Sydney,Australia.

Department of Otolaryngology,St Vincent's Private Hospital,Sydney,Australia.

出版信息

J Laryngol Otol. 2017 Jan;131(S1):S47-S49. doi: 10.1017/S002221511600935X.

Abstract

BACKGROUND

Studies demonstrate the significance of intra- and inter-observer variability when measuring cerebellopontine angle tumours on magnetic resonance imaging, with measured differences as high as 2 mm.

OBJECTIVE

To determine intra- and inter-observer measurement variability of cerebellopontine angle tumours in a specialised institution.

METHODS

The magnetic resonance imaging maximal diameter of 12 randomly selected cerebellopontine angle tumours were independently measured by 4 neuroradiologists at a tertiary referral centre using a standard definition for maximal tumour diameter. Average deviation and intraclass correlation were subsequently calculated.

RESULTS

Inter-observer difference averaged 0.33 ± 0.04 mm (range, 0.0-0.8 mm). Intra-observer measurements were more consistent than inter-observer measurements, with differences averaging 0.17 mm (95 per cent confidence interval = 0.27-0.06, p = 0.002). Inter-observer reliability was 0.99 (95 per cent confidence interval = 0.97-0.99), suggesting high reliability between the readings.

CONCLUSION

The use of a standard definition for maximal tumour volume provided high reliability amongst radiologists' readings. To avoid oversizing tumours, it is recommended that conservative monitoring be conducted by the same institution with thin slice magnetic resonance imaging scans.