Abstract

Calorimetric biochemical measurements offer various advantages such as low waste, low cost, low sample consumption, short operating time, and labor-savings. Multichannel calorimeters can enhance the possibility of performing higher-throughput biochemical measurements. An enthalpy sensor (ES) array is a key device in multichannel calorimeters. Most ES arrays use Wheatstone bridge amplifiers to condition the sensor signals, but such an approach is only suitable for null detection and low resistance sensors. To overcome these limitations, we have developed a multichannel calorimetric simultaneous assay (MCSA) platform. An adjustable microampere constant-current (AMCC) source was designed for exciting the ES array using a microampere current loop measurement circuit topology. The MCSA platform comprises a measurement unit, which contains a multichannel calorimeter and an automatic simultaneous injector, and a signal processing unit, which contains multiple ES signal conditioners and a data processor. This study focused on the construction of the MCSA platform; in particular, construction of the measurement circuit and calorimeter array in a single block. The performance of the platform, including current stability, temperature sensitivity and heat sensitivity, was evaluated. The sensor response time and calorimeter constants were given. The capability of the platform to detect relative enzyme activity was also demonstrated. The experimental results show that the proposed MCSA is a flexible and powerful biochemical measurement device with higher throughput than existing alternatives.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b3c4/5335969/2a0e27ae9af0/sensors-17-00292-g001.jpg

相似文献

2
Fabrication and characterization of a multichannel 3D thermopile for chip calorimeter applications.
Sensors (Basel). 2015 Feb 3;15(2):3351-61. doi: 10.3390/s150203351.
3
A 0.18 μm CMOS LDO Regulator for an On-Chip Sensor Array Impedance Measurement System.
Sensors (Basel). 2018 May 2;18(5):1405. doi: 10.3390/s18051405.
5
A paper-based calorimetric microfluidics platform for bio-chemical sensing.
Biosens Bioelectron. 2014 Sep 15;59:120-6. doi: 10.1016/j.bios.2014.03.022. Epub 2014 Mar 27.
7
Single-Line Multi-Channel Flexible Stress Sensor Arrays.
Micromachines (Basel). 2023 Aug 3;14(8):1554. doi: 10.3390/mi14081554.
8
Micro-fabricated DC comparison calorimeter for RF power measurement.
Sensors (Basel). 2014 Oct 27;14(11):20245-61. doi: 10.3390/s141120245.
9
Micro-differential scanning calorimeter for liquid biological samples.
Rev Sci Instrum. 2016 Oct;87(10):105005. doi: 10.1063/1.4965443.
10
The Snellen human calorimeter revisited, re-engineered and upgraded: design and performance characteristics.
Med Biol Eng Comput. 2006 Aug;44(8):721-8. doi: 10.1007/s11517-006-0086-5. Epub 2006 Jul 25.

本文引用的文献

1
Fabrication and characterization of a multichannel 3D thermopile for chip calorimeter applications.
Sensors (Basel). 2015 Feb 3;15(2):3351-61. doi: 10.3390/s150203351.
2
Higher throughput calorimetry: opportunities, approaches and challenges.
Curr Opin Struct Biol. 2010 Oct;20(5):598-605. doi: 10.1016/j.sbi.2010.09.001. Epub 2010 Oct 1.
3
Catalase deficiency and type 2 diabetes.
Diabetes Care. 2008 Dec;31(12):e93. doi: 10.2337/dc08-1607.
4
Enthalpy array analysis of enzymatic and binding reactions.
Anal Biochem. 2008 Jun 1;377(1):33-9. doi: 10.1016/j.ab.2008.03.007. Epub 2008 Mar 7.
5
Enthalpy arrays.
Proc Natl Acad Sci U S A. 2004 Jun 29;101(26):9517-22. doi: 10.1073/pnas.0403573101. Epub 2004 Jun 21.
7
Applications of calorimetric methods to drug discovery and the study of protein interactions.
Curr Opin Struct Biol. 2003 Feb;13(1):115-21. doi: 10.1016/s0959-440x(03)00003-4.
8
Blood catalase deficiency and diabetes in Hungary.
Diabetes Care. 2001 Oct;24(10):1839-40. doi: 10.2337/diacare.24.10.1839.
10
A simple method for determination of serum catalase activity and revision of reference range.
Clin Chim Acta. 1991 Feb 15;196(2-3):143-51. doi: 10.1016/0009-8981(91)90067-m.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验