Suppr超能文献

平板探测器CT在脑动静脉畸形灌注评估中的可行性:初步临床经验

Feasibility of Flat Panel Detector CT in Perfusion Assessment of Brain Arteriovenous Malformations: Initial Clinical Experience.

作者信息

Garcia M, Okell T W, Gloor M, Chappell M A, Jezzard P, Bieri O, Byrne J V

机构信息

From the Division of Diagnostic and Interventional Neuroradiology (M. Garcia)

Nuffield Department of Surgical Sciences and Department of Neuroradiology (M. Garcia, J.V.B.).

出版信息

AJNR Am J Neuroradiol. 2017 Apr;38(4):735-739. doi: 10.3174/ajnr.A5091. Epub 2017 Feb 16.

Abstract

The different results from flat panel detector CT in various pathologies have provoked some discussion. Our aim was to assess the role of flat panel detector CT in brain arteriovenous malformations, which has not yet been assessed. Five patients with brain arteriovenous malformations were studied with flat panel detector CT, DSC-MR imaging, and vessel-encoded pseudocontinuous arterial spin-labeling. In glomerular brain arteriovenous malformations, perfusion was highest next to the brain arteriovenous malformation with decreasing values with increasing distance from the lesion. An inverse tendency was observed in the proliferative brain arteriovenous malformation. Flat panel detector CT, originally thought to measure blood volume, correlated more closely with arterial spin-labeling-CBF and DSC-CBF than with DSC-CBV. We conclude that flat panel detector CT perfusion depends on the time point chosen for data collection, which is triggered too early in these patients (ie, when contrast agent appears in the superior sagittal sinus after rapid shunting through the brain arteriovenous malformation). This finding, in combination with high data variability, makes flat panel detector CT inappropriate for perfusion assessment in brain arteriovenous malformations.

摘要

平板探测器CT在各种病变中的不同结果引发了一些讨论。我们的目的是评估平板探测器CT在脑动静脉畸形中的作用,这尚未得到评估。对5例脑动静脉畸形患者进行了平板探测器CT、动态磁敏感对比增强磁共振成像(DSC-MR成像)和血管编码伪连续动脉自旋标记研究。在肾小球型脑动静脉畸形中,脑动静脉畸形旁的灌注最高,随着与病变距离的增加而降低。在增殖型脑动静脉畸形中观察到相反的趋势。平板探测器CT最初被认为是测量血容量的,与动脉自旋标记脑血流量(ASL-CBF)和DSC脑血流量(DSC-CBF)的相关性比与DSC脑血容量(DSC-CBV)更密切。我们得出结论,平板探测器CT灌注取决于选择的数据采集时间点,在这些患者中触发过早(即造影剂在通过脑动静脉畸形快速分流后出现在上矢状窦时)。这一发现,再加上高数据变异性,使得平板探测器CT不适用于脑动静脉畸形的灌注评估。

相似文献

本文引用的文献

4
Cerebral blood flow quantification using vessel-encoded arterial spin labeling.基于血管编码动脉自旋标记的脑血流定量。
J Cereb Blood Flow Metab. 2013 Nov;33(11):1716-24. doi: 10.1038/jcbfm.2013.129. Epub 2013 Aug 7.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验