Hirano Ikuo, Pandolfino John E, Boeckxstaens Guy E
Department of Medicine, Division of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
Department of Gastroenterology, Translational Research Center for Gastrointestinal Disorders, University Hospital Leuven, Catholic University of Leuven, Leuven, Belgium.
Clin Gastroenterol Hepatol. 2017 Mar;15(3):325-334. doi: 10.1016/j.cgh.2016.10.022.
The functional luminal imaging probe is a Food and Drug Administration-approved measurement tool used to measure simultaneous pressure and diameter to guide management of various upper gastrointestinal disorders. Additionally, this tool is also approved to guide therapy during bariatric procedures and specialized esophageal surgery. Although it has been commercially available since 2009 as the endolumenal functional lumen imaging probe (EndoFLIP), the functional luminal imaging probe has had limited penetrance into clinical settings outside of specialized centers. This is primarily because of a paucity of data supporting its utility in general practice and a lack of standardized protocols and data analysis methodology. However, data are accumulating that are providing guidance regarding emerging applications in the evaluation and management of foregut disorders. This clinical practice update describes the technique and reviews potential indications in achalasia, eosinophilic esophagitis, and gastroesophgeal reflux disease. Best Practice Advice 1: Clinicians should not make a diagnosis or treatment decision based on functional lumen imaging probe (FLIP) assessment alone. Best Practice Advice 2: FLIP assessment is a complementary tool to assess esophagogastric junction opening dynamics and the stiffness of the esophageal wall. Best Practice Advice 3: Utilization should follow distinct protocols and analysis paradigms based on the disease state of interest. Best Practice Advice 4: Clinicians should not utilize FLIP in routine diagnostic assessments of gastroesophageal reflux disease. Best Practice Advice 5: FLIP should not be used to diagnose eosinophilic esophagitis but may have a role in severity assessment and therapeutic monitoring.
功能性管腔成像探头是一种经美国食品药品监督管理局批准的测量工具,用于同时测量压力和直径,以指导各种上消化道疾病的管理。此外,该工具还被批准用于指导减肥手术和专门的食管手术中的治疗。尽管自2009年以来它作为腔内功能性管腔成像探头(EndoFLIP)已在市场上销售,但功能性管腔成像探头在专业中心以外的临床环境中的渗透率有限。这主要是因为缺乏支持其在一般实践中效用的数据,以及缺乏标准化的协议和数据分析方法。然而,越来越多的数据正在为前肠疾病评估和管理中的新兴应用提供指导。本临床实践更新描述了该技术,并回顾了在贲门失弛缓症、嗜酸性食管炎和胃食管反流病中的潜在适应症。最佳实践建议1:临床医生不应仅基于功能性管腔成像探头(FLIP)评估做出诊断或治疗决定。最佳实践建议2:FLIP评估是评估食管胃交界开放动态和食管壁硬度的辅助工具。最佳实践建议3:应根据感兴趣的疾病状态遵循不同的协议和分析范式。最佳实践建议4:临床医生不应在胃食管反流病的常规诊断评估中使用FLIP。最佳实践建议5:FLIP不应用于诊断嗜酸性食管炎,但可能在严重程度评估和治疗监测中发挥作用。