Suppr超能文献

车辆类型会影响通过光学相干断层扫描成像的分数激光消融通道的填充情况。

Vehicle type affects filling of fractional laser-ablated channels imaged by optical coherence tomography.

作者信息

Olesen Uffe Høgh, Mogensen Mette, Haedersdal Merete

机构信息

Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Bispebjerg Bakke 23, DK-2400, Copenhagen, NV, Denmark.

出版信息

Lasers Med Sci. 2017 Apr;32(3):679-684. doi: 10.1007/s10103-017-2168-z. Epub 2017 Feb 17.

Abstract

Ablative fractional laser (AFXL) is an emerging method that enhances topical drug delivery. Penetrating the skin in microscopic, vertical channels, termed microscopic treatment zones (MTZs), the fractional technique circumvents the skin barrier and allows increased uptake of topically applied drugs. This study aims to elucidate the impact of vehicle type on the filling of MTZs from application of liquid, gel, and cream vehicles. Ex vivo pig skin was exposed to 10,600 nm fractional CO laser at 5% density, 120 μm beam diameter, and fluences of 40 and 80 mJ/microbeam (mJ/mb). Six repetitions were performed for each of six interventions (2 fluences and 3 vehicle types, n = 36). MTZ dimensions and filling by vehicle type were evaluated by optical coherence tomography, using blue tissue dye as a contrast-enhancing agent. Outcome measure was degree of MTZ filling assessed as percentages of empty, partially filled, and completely filled MTZs (108-127 MTZs/intervention analyzed) and evaluated statistically using Kruskal-Wallis and Dunn's tests. MTZs reached mid-dermal levels of 225 μm (40 mJ/mb) and 375 μm (80 mJ/mb) penetration depths (p < 0.0001). Filling of MTZs depended on type of applied vehicle. At 80 mJ/mb, liquid (67% completely filled, p < 0.01) and gel (60%, p < 0.05) formulations filled MTZs significantly better than cream formulation (31%). At 40 mJ/mb, liquid and gel formulations filled 90% (p < 0.05) and 77% (p > 0.05) of MTZs completely versus 55% for cream formulation. Thus, filling was overall greater for more superficial MTZs. In conclusion, vehicle type affects filling of MTZs, which may be of importance for AFXL-assisted drug delivery.

摘要

剥脱性分数激光(AFXL)是一种新兴的增强局部药物递送的方法。这种分数技术通过在微观垂直通道(称为微观治疗区,MTZs)穿透皮肤,绕过了皮肤屏障,使局部应用药物的吸收增加。本研究旨在阐明载体类型对液体、凝胶和乳膏载体应用后MTZs填充情况的影响。将离体猪皮暴露于波长为10,600 nm的分数CO激光下,密度为5%,光束直径为120μm,微束能量密度为40和80 mJ/microbeam(mJ/mb)。对六种干预措施(2种能量密度和3种载体类型)中的每一种进行六次重复操作(n = 36)。使用蓝色组织染料作为造影剂,通过光学相干断层扫描评估MTZ尺寸和载体类型的填充情况。结果测量指标是MTZ填充程度,以空的、部分填充的和完全填充的MTZs的百分比来评估(每次干预分析108 - 127个MTZs),并使用Kruskal - Wallis检验和Dunn检验进行统计学评估。MTZs达到真皮中层水平,穿透深度分别为225μm(40 mJ/mb)和375μm(80 mJ/mb)(p < 0.0001)。MTZs的填充取决于所应用载体的类型。在80 mJ/mb时,液体(67%完全填充,p < 0.01)和凝胶(60%,p < 0.05)制剂填充MTZs的效果明显优于乳膏制剂(31%)。在40 mJ/mb时,液体和凝胶制剂分别有90%(p < 0.05)和77%(p > 0.05)的MTZs完全填充,而乳膏制剂为55%。因此,对于较浅的MTZs,总体填充情况更好。总之,载体类型会影响MTZs的填充,这对于AFXL辅助药物递送可能具有重要意义。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验