Oturina Vera, Hammer Kerstin, Möllers Mareike, Braun Janina, Falkenberg Maria Karina, de Murcia Kathrin Oelmeier, Möllmann Ute, Eveslage Maria, Fruscalzo Arrigo, Klockenbusch Walter, Schmitz Ralf
.
J Perinat Med. 2017 Nov 27;45(8):925-932. doi: 10.1515/jpm-2016-0375.
The aim of the study was to assess the cervical strain pattern by an ultrasound elastography cervix examination and to determine its association with preterm delivery.
In this study, 30 cases resulting in preterm birth and 30 gestational age-matched controls were included. A vaginal ultrasound examination with cervical length and elastography measurement was performed. We calculated four strain ratios (SR1-SR4) of the regions of interest (ROIs) arranged in pairs in four different positions on the anterior cervical lip. The strain ratios were correlated to the outcome of spontaneous preterm delivery. The inter-observer and intra-observer variability of the strain measurement was evaluated.
We observed an association between the value of the strain ratio that was calculated from the ROIs placed side by side in the middle of the anterior lip (SR4), and preterm delivery (P<0.001). The predictive values of cervical length and SR4 were comparable (AUC 0.7394; AUC 0.8322, respectively). The combination of cervical length and SR4 was superior in predicting preterm delivery compared to both parameters alone (AUC 0.8789). The inter-observer and intra-observer variability of data acquisition and measurement was excellent.
Our study assesses the cervical elastography strain pattern and shows a correlation to a spontaneous preterm birth.
本研究旨在通过超声弹性成像宫颈检查评估宫颈应变模式,并确定其与早产的关联。
本研究纳入了30例早产病例和30例孕周匹配的对照。进行了宫颈长度和弹性成像测量的经阴道超声检查。我们计算了宫颈前唇四个不同位置成对排列的感兴趣区域(ROI)的四个应变比(SR1 - SR4)。应变比与自然早产的结局相关。评估了应变测量的观察者间和观察者内变异性。
我们观察到在前唇中部并排放置的ROI计算出的应变比(SR4)值与早产之间存在关联(P < 0.001)。宫颈长度和SR4的预测价值相当(AUC分别为0.7394和0.8322)。与单独的两个参数相比,宫颈长度和SR4的组合在预测早产方面更优(AUC为0.8789)。数据采集和测量的观察者间和观察者内变异性良好。
我们的研究评估了宫颈弹性成像应变模式,并显示出与自然早产的相关性。