Suppr超能文献

基于3D踝关节MRI的模拟放射学骨与关节建模:可行性及与X线片和2D MRI的比较

Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI.

作者信息

Nordeck Shaun M, Koerper Conrad E, Adler Aaron, Malhotra Vidur, Xi Yin, Liu George T, Chhabra Avneesh

机构信息

University of Texas Southwestern Medical College, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.

Musculoskeletal Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA.

出版信息

Skeletal Radiol. 2017 May;46(5):651-664. doi: 10.1007/s00256-017-2596-7. Epub 2017 Mar 6.

Abstract

PURPOSE

The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities.

MATERIALS AND METHODS

Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant.

RESULTS

Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements.

CONCLUSIONS

Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR.

摘要

目的

本研究旨在从各向同性的3D MRI数据模拟X线片,比较模拟X线片上角度和关节间隙测量值与相应2D MRI及真实X线片(XR)之间的关系,并比较三种检查方式的测量时间。

材料与方法

纳入连续的24例踝关节,其中男性8例,女性16例,平均年龄46岁。从3D MRI数据集中创建模拟X线片的关节分割模型。三位阅片者在两个时间点对模型、相应的2D MRI及XR独立进行盲法角度和关节间隙测量。确定线性混合模型和组内相关系数(ICC),p值小于0.05认为具有统计学意义。

结果

所有病例均成功创建模拟X线片模型。所有阅片者在所有检查方式及大多数测量中均观察到良好的一致性(ICC>0.65)。不同检查方式的绝对测量值存在差异。大多数测量中,2D与模拟X线片相比测量时间显著更长(p<0.05),近一半测量中XR与模拟X线片相比测量时间显著更长(p<0.05)。

结论

可从3D MRI数据成功生成模拟X线片;然而,测量值有所不同。观察到阅片者间具有良好的可靠性,阅片者内具有中度至良好的可靠性,与2D测量相比,模拟X线片模型测量所需时间显著更短,且通常比XR测量所需时间更少。