• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of Topogram-based Automated Selection of Tube Potential and Fixed Tube Potential in Imaging Solid Pancreatic Lesions.

作者信息

Xu Kai, Zhu Liang, Xue Huadan, Li Ping, Sun Zhaoyong, DU Yao, Wang Yun, Jin Zhengyu

机构信息

Department of Radiology,PUMC Hospital,CAMS and PUMC,Beijing 100730,China.

出版信息

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2017 Feb 20;39(1):88-94. doi: 10.3881/j.issn.1000-503X.2017.01.015.

DOI:10.3881/j.issn.1000-503X.2017.01.015
PMID:28270289
Abstract

Objective To evaluate the image quality and radiation exposure in multidetector computed tomography (MDCT) with automated topogram-based tube potential selection,compared to fixed tube potential,in patients with solid pancreatic lesions. Methods The preoperative pancreatic dual-source CT images of 113 patients who were confirmed as solid pancreatic lesions by postoperative pathology in the Peking Union Medical College Hospital from January 2014 to August 2016 were retrospectively analyzed.Among them,53 patients were examined on fixed tube potential at 120 kV,and tube current was automatically modulated (group 1). Sixty patients underwent topogram-based automatic tube potential selection (Tube voltage step:90,100 kV) and automated mA modulation (group 2). Two experienced radiologists measured the body sizes,assessed subjective and objective image quality of arterial phase and portal phase,and recorded radiation parameters including CT dose index volume (CTDI) and dose-length product (DLP). Results Of 60 patients in group 2,45 patients were scaned at 90 kV,15 patients were scaned at 100 kV.The average body diameter [(287±24) mm] in 90 kV group was significantly lower than that [(328±22) mm] in 100 kV group(t=0.731,P=0.0008). The mean CTDI [(3.9±1.0) mGy] in group 2 was significantly lower than in group 1 [(9.0±1.9) mGy],reduced by 56.7% (t=17.5,P=0.0003). The average DLP [(109±38) mGy·cm] in group 2 was significantly lower than that in group 1 [(276±83) mGy·cm],reduced by 60.5% (t=14.0,P=0.0007). In group 2,the standard deviations of images background noise in arterial and portal phase were (6.4±0.9) and (6.4±1.0)HU,respectively,which were significantly higher than those in group 1 [(5.6±1.4)HU,t=-3.757,P=0.0003;(5.5±1.4)HU,t=-3.828,P=0.0006]. In group 2,the signal to noise ratios of pancreatic lesions, abdominal aorta in arterial phase and pancreatic lesions, the portal vein in portal phase were 18.8±9.3,76.0±19.3 and 17.4±6.7,33.1±7.2,which were significantly higher than those in group 1 (13.1±8.7,t=-3.379,P=0.001;56.5±22.6,t=-2.268,P=0.025;14.1±8.1,t=-2.283,P=0.024;28.9±8.8,t=-2.613,P=0.009). Conclusion Compared with fixed tube voltage on the second-generation dual-source CT techniques,topogram-based automatic tube potential selection on third-generation dual-source CT can reduce radiation dose without decreasing image quality in imaging solid pancreatic lesions.

摘要

相似文献

1
Comparison of Topogram-based Automated Selection of Tube Potential and Fixed Tube Potential in Imaging Solid Pancreatic Lesions.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2017 Feb 20;39(1):88-94. doi: 10.3881/j.issn.1000-503X.2017.01.015.
2
Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.基于定位像的胸腹创伤CT管电压和管电流自动选择——与仅采用毫安秒调制的固定千伏比较
Eur Radiol. 2014 Jul;24(7):1725-34. doi: 10.1007/s00330-014-3197-7. Epub 2014 May 10.
3
A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm.使用低浓度碘化造影剂、低管电压并结合70%自适应统计迭代重建(ASIR)算法对小儿腹部增强CT扫描的对比度、辐射剂量和图像质量进行前瞻性评估。
Int J Clin Pract. 2016 Sep;70 Suppl 9B:B16-21. doi: 10.1111/ijcp.12853.
4
Single-energy low-voltage arterial phase MDCT scanning increases conspicuity of adenocarcinoma of the pancreas.单能量低千伏动脉期 MDCT 扫描提高胰腺腺癌的显影度。
Eur J Radiol. 2014 Mar;83(3):e113-7. doi: 10.1016/j.ejrad.2013.12.022. Epub 2014 Jan 5.
5
Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols.成人和儿科多层螺旋CT中的预估患者剂量指数:自动管电压选择与固定管电流、固定管电压及体重基础方案的比较
AJR Am J Roentgenol. 2015 Sep;205(3):592-8. doi: 10.2214/AJR.14.13242.
6
Automated Attenuation Based Tube Potential Selection of the Lower Extremity Runoff: A Comparison to Fixed Kilovolt with Automated Tube Current Modulation.基于自动衰减的下肢血管造影管电压选择:与自动管电流调制下的固定千伏对比
J Comput Assist Tomogr. 2017 Sep/Oct;41(5):817-822. doi: 10.1097/RCT.0000000000000602.
7
Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness.基于自动衰减的胸腹部 CT 血管造影管电压选择:提高剂量效率。
Invest Radiol. 2011 Dec;46(12):767-73. doi: 10.1097/RLI.0b013e3182266448.
8
Automated tube voltage adaptation in combination with advanced modeled iterative reconstruction in thoracoabdominal third-generation 192-slice dual-source computed tomography: effects on image quality and radiation dose.胸腹第三代192层双源计算机断层扫描中自动管电压适配与先进的模型迭代重建相结合:对图像质量和辐射剂量的影响
Acad Radiol. 2015 Sep;22(9):1081-7. doi: 10.1016/j.acra.2015.05.010. Epub 2015 Jul 9.
9
Automated Tube Potential Selection as a Method of Dose Reduction for CT of the Neck: First Clinical Results.自动管电压选择作为颈部 CT 剂量降低的一种方法:初步临床结果。
AJR Am J Roentgenol. 2015 May;204(5):1049-54. doi: 10.2214/AJR.14.12975.
10
Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.第三代双源CT系统上的单源胸部-腹部-骨盆癌症分期:自动管电压选择与第二代双源CT的比较
Cancer Imaging. 2016 Oct 10;16(1):33. doi: 10.1186/s40644-016-0093-1.