Meenakshi Ammal Dental College & Hospital, Department of Conservative Dentistry and Endodontics, Maduravoyal, Chennai, 600095, India.
J Prosthodont Res. 2017 Oct;61(4):464-470. doi: 10.1016/j.jpor.2017.02.001. Epub 2017 Mar 6.
This in-vitro study tested the fracture resistance of endodontically treated molars with Mesial-Occluso-Distal (MOD) cavities restored with fibre reinforced composite material everX posterior in comparision with hybrid composite and ribbond fiber composite.
Fifty intact freshly extracted human mandibular first molars were collected and were randomly divided into five groups (n=10). Group 1: positive control (PC) intact teeth without any endodontic preparation. In groups 2 through 6 after endodontic procedure standard MOD cavities were prepared and restored with their respective core materials as follows: group 2, negative control (NC) left unrestored or temporary flling was applied. Group 3, Hybrid composite (HC) as a core material (Te-Econom Plus Ivoclar Vivadent Asia) group 4, Ribbond (Ribbond; Seattle, WA, USA)+conventional composite resin (RCR) group 5, everX posterior (everX Posterior GC EUROPE)+conventional composite resin (EXP) after thermocycling fracture resistance for the samples were tested using universal testing machine. The results were analysed using ANOVA and Tukey's HSD post hoc tests.
Mean fracture resistance (in Newton, N) was group 1: 1568.4±221.71N, group 2: 891.0±50.107N, group 3: 1418.3±168.71N, group 4:1716.7±199.51N and group 5: 1994.8±254.195N.
Among the materials tested, endodontically treated teeth restored with everX posterior fiber reinforced composite showed superior fracture resistance.
本体外研究测试了用纤维增强复合材料 everX posterior 修复近中-颊-远(MOD)腔的牙髓治疗磨牙的抗断裂能力,与混合复合材料和 Ribbond 纤维复合材料进行比较。
收集了 50 颗完整的新鲜离体下颌第一磨牙,并将其随机分为 5 组(n=10)。第 1 组:阳性对照(PC)未经任何牙髓预备的完整牙齿。在第 2 至 6 组中,在牙髓治疗后制备标准 MOD 腔,并使用各自的核材料进行修复,如下所示:第 2 组,阴性对照(NC)左侧未修复或应用临时填充。第 3 组,混合复合材料(HC)作为核材料(Te-Econom Plus Ivoclar Vivadent Asia)第 4 组,Ribbond(Ribbond;西雅图,WA,美国)+常规复合树脂(RCR)第 5 组,everX posterior(everX Posterior GC EUROPE)+常规复合树脂(EXP)经过热循环后,使用万能试验机对样本进行抗断裂能力测试。使用方差分析和 Tukey 的 HSD 事后检验对结果进行分析。
平均断裂阻力(以牛顿,N 计)为第 1 组:1568.4±221.71N,第 2 组:891.0±50.107N,第 3 组:1418.3±168.71N,第 4 组:1716.7±199.51N 和第 5 组:1994.8±254.195N。
在所测试的材料中,用 everX posterior 纤维增强复合材料修复的牙髓治疗牙齿显示出更高的抗断裂能力。