• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Cat on a Hot Tin Roof: Mechanical Testing of Models of Tourniquets After Environmental Exposure.

作者信息

O'Conor Daniel K, Kragh John F, Aden James K, Dubick Michael A

出版信息

J Spec Oper Med. 2017 Spring;17(1):27-35. doi: 10.55460/V2L7-IR4Q.

DOI:10.55460/V2L7-IR4Q
PMID:28285478
Abstract

BACKGROUND

The purpose of the present study was to mechanically assess models of emergency tourniquet after 18 months of environmental exposure to weather to better understand risk of component damage.

MATERIALS AND METHODS

An experiment was designed to test tourniquet performance on a manikin thigh. Three tourniquet models were assessed: Special Operations Forces Tactical Tourniquet Wide, Ratcheting Medical Tourniquet, and Combat Application Tourniquet. Unexposed tourniquets formed a control group stored in a laboratory; exposed tourniquets were placed outdoors on a metal roof for 18 months in San Antonio, Texas. Two users, a military cadet and a scientist, made 300 assessments in total. Assessment included major damage (yes-no), effectiveness (hemorrhage control, yes-no), casualty survival (alive-dead), time to stop bleeding, pressure, and blood loss. Time, pressure, and blood loss were reported in tests with effectiveness.

RESULTS

Exposed devices had worse results than unexposed devices for major damage (3% [4/150] versus 0% [0/150]; ρ = .018), effectiveness (89% versus 99%; ρ = .002), and survival of casualties (89% versus 100%; ρ < .001). In tests for effectiveness, exposed devices had worse results than unexposed devices for time to stop bleeding (29 seconds versus 26 seconds; ρ = .01) and pressure (200mmHg versus 204mmHg; ρ = .03, respectively), but blood loss volume did not differ significantly.

CONCLUSION

Compared with unexposed control devices, environmentally exposed tourniquets had worse results in tests of component damage, effectiveness, and casualty survival.

摘要

相似文献

1
Cat on a Hot Tin Roof: Mechanical Testing of Models of Tourniquets After Environmental Exposure.
J Spec Oper Med. 2017 Spring;17(1):27-35. doi: 10.55460/V2L7-IR4Q.
2
Preliminary Comparison of New and Established Tactical Tourniquets in a Manikin Hemorrhage Model.
J Spec Oper Med. 2016 Spring;16(1):29-35.
3
Laboratory testing of emergency tourniquets exposed to prolonged heat.
J Spec Oper Med. 2015 Spring;15(1):34-8.
4
Preliminary Comparison of Pneumatic Models of Tourniquet for Prehospital Control of Limb Bleeding in a Manikin Model.院前人体模型肢体出血控制中止血带气动模型的初步比较
J Spec Oper Med. 2016 summer;16(2):21-7.
5
Evaluation of Models of Pneumatic Tourniquet in Simulated Out-of-Hospital Use.模拟院外使用的气动止血带模型评估
J Spec Oper Med. 2016 fall;16(3):21-29. doi: 10.55460/EGF9-LBSQ.
6
Assessment of Groin Application of Junctional Tourniquets in a Manikin Model.在人体模型中评估腹股沟处使用交界性止血带的情况。
Prehosp Disaster Med. 2016 Aug;31(4):358-63. doi: 10.1017/S1049023X16000443. Epub 2016 May 27.
7
External Soft-Tissue Hemostatic Clamp Compared to a Compression Tourniquet as Primary Hemorrhage Control Device in Pilot Flow Model Study.在初步血流模型研究中,外部软组织止血夹与压迫止血带相比,作为主要的止血控制装置。
Prehosp Disaster Med. 2019 Apr;34(2):175-181. doi: 10.1017/S1049023X19000037. Epub 2019 Mar 27.
8
Role of the Windlass in Improvised Tourniquet Use on a Manikin Hemorrhage Model.止血带在人体模型出血模型上用于简易止血带操作中的作用。
J Spec Oper Med. 2015 Summer;15(2):42-46. doi: 10.55460/DTPO-G5OG.
9
Belts Evaluated as Limb Tourniquets: BELT Study Comparing Trouser Supporters Used as Medical Devices in a Manikin Model of Wound Bleeding.
Wilderness Environ Med. 2017 Jun;28(2):84-93. doi: 10.1016/j.wem.2017.01.030. Epub 2017 Apr 20.
10
Short Report Comparing Generation 6 Versus Prototype Generation 7 Combat Application Tourniquet® in a Manikin Hemorrhage Model.简短报告:在人体模型出血模型中比较第6代与第7代原型Combat Application Tourniquet®止血带
J Spec Oper Med. 2016 Spring;16(1):14-7.