Suppr超能文献

站立位足踝部X线片观察到的负重情况高度可变。

High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.

作者信息

Miller Christopher P, Ghorbanhoseini Mohammad, Ehrlichman Lauren K, Walley Kempland C, Ghaheri Azadeh, Kwon John Y

机构信息

1 Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.

2 Naval Hospital Beaufort, Beaufort, SC, USA.

出版信息

Foot Ankle Int. 2017 Jun;38(6):690-693. doi: 10.1177/1071100717695361. Epub 2017 Mar 13.

Abstract

BACKGROUND

Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest.

METHODS

Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing.

RESULTS

The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002).

CONCLUSIONS

There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs.

LEVEL OF EVIDENCE

Level III, comparative study.

摘要

背景

负重位X线片是评估足踝部病变的关键组成部分。一个潜在的假设是,患者在图像采集过程中将其体重的50%置于患足上。X线片拍摄过程中负重的准确性尚不清楚,而且据推测是可变的,这可能导致所得X线片描绘感兴趣病变的能力不确定。

方法

对50名受试者进行测试。在X线图像采集瞬间测量通过患足的体重百分比。然后指示受试者在下一次X线片拍摄前承受“一半体重”。计算体重百分比并与理想的50%负重进行比较。

结果

试验1和试验2中的平均体重百分比分别为45.7%±3.2%(与50%标记相比,P = 0.012)和49.2%±2.4%(与50%相比,P = 0.428)。试验1和试验2中与50%相比的平均负重百分比绝对差异分别为9.3%±2.3%和5.8%±1.8%(P = 0.005)。在试验1中,18/50的受试者负重处于“理想”(4

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验