Suppr超能文献

使用计算机断层扫描小肠造影评估克罗恩病患者:检查者的经验对该方法的可重复性有何影响?

Using computed tomography enterography to evaluate patients with Crohn's disease: what impact does examiner experience have on the reproducibility of the method?

作者信息

Burlin Stênio, Favaro Larissa Rossini, Bretas Elisa Almeida Sathler, Taniguchi Lincoln Seiji, Loch Ana Paula, Argollo Marjorie Costa, Ambrogini Junior Orlando, D'Ippolito Giuseppe

机构信息

MD, Radiologist in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.

MD, Radiologist, Specialist in Abdominal Imaging in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.

出版信息

Radiol Bras. 2017 Jan-Feb;50(1):13-18. doi: 10.1590/0100-3984.2015.0131.

Abstract

OBJECTIVE

To assess the impact that examiner experience has on the reproducibility and accuracy of computed tomography (CT) enterography in the detection of radiological signs in patients with Crohn's disease.

MATERIALS AND METHODS

This was a retrospective, cross-sectional observational study involving the analysis of CT enterography scans of 20 patients with Crohn's disease. The exams were analyzed independently by two radiologists in their last year of residence (duo I) and by two abdominal imaging specialists (duo II). The interobserver agreement of each pair of examiners in identifying the main radiological signs was calculated with the kappa test. The accuracy of the examiners with less experience was quantified by using the consensus among three experienced examiners as a reference.

RESULTS

Duo I and duo II obtained a similar interobserver agreement, with a moderate to good correlation, for mural hyperenhancement, parietal thickening, mural stratification, fat densification, and comb sign (kappa: 0.45-0.64). The less experienced examiners showed an accuracy > 80% for all signs, except for lymph nodes and fistula, for which it ranged from 60% to 75%.

CONCLUSION

Less experienced examiners have a tendency to present a level of interobserver agreement similar to that of experienced examiners in evaluating Crohn's disease through CT enterography, as well as showing satisfactory accuracy in identifying most radiological signs of the disease.

摘要

目的

评估检查者经验对克罗恩病患者计算机断层扫描(CT)小肠造影中放射学征象检测的可重复性和准确性的影响。

材料与方法

这是一项回顾性横断面观察性研究,涉及对20例克罗恩病患者的CT小肠造影扫描进行分析。这些检查由两名住院医师最后一年的放射科医生(第一组)和两名腹部影像专家(第二组)独立分析。使用kappa检验计算每对检查者在识别主要放射学征象方面的观察者间一致性。以三名经验丰富的检查者之间的共识为参考,对经验较少的检查者的准确性进行量化。

结果

第一组和第二组在肠壁强化、肠壁增厚、肠壁分层、脂肪密度增加和梳征方面获得了相似的观察者间一致性,相关性为中度至良好(kappa值:0.45 - 0.64)。经验较少的检查者对所有征象的准确率均>80%,但淋巴结和瘘管的准确率为60%至75%。

结论

经验较少的检查者在通过CT小肠造影评估克罗恩病时,其观察者间一致性水平往往与经验丰富的检查者相似,并且在识别该疾病的大多数放射学征象方面显示出令人满意的准确性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d44b/5347498/d308aea13751/rb-50-01-0013-g01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验