Suppr超能文献

使用口内和口外扫描仪的CAD系统用于固定义齿设计的准确性。

The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

作者信息

Shimizu Sakura, Shinya Akikazu, Kuroda Soichi, Gomi Harunori

机构信息

Department of Crown and Bridge, School of Life Dentistry at Tokyo, The Nippon Dental University.

出版信息

Dent Mater J. 2017 Jul 26;36(4):402-407. doi: 10.4012/dmj.2016-326. Epub 2017 Mar 8.

Abstract

The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

摘要

修复体的精度会影响临床成功率,而其又反过来受扫描仪和计算机辅助设计(CAD)程序精度的影响。因此,它们的精度很重要。本研究的首要目的是评估具有主动三角测量功能的口内扫描仪(西诺德全瓷牙切削系统Omnicam)、具有共聚焦激光的口内扫描仪(3Shape Trios)以及具有主动三角测量功能的口外扫描仪(尼康D810)的精度。本研究的第二个目的是比较使用两种不同扫描仪/CAD组合设计的数字牙冠的精度。口内扫描仪和口外扫描仪的精度在临床上是可接受的。使用口内扫描仪和CAD程序制作的数字牙冠的边缘适合性和内部适合性低于使用口外扫描仪和CAD程序制作的数字牙冠。