Abstract

We report preliminary results of our experiments directed at fabricating pH-sensitive electrodes suitable for in vivo use by means of thick film screening techniques. Our results show that glass membranes of suitable thickness and possessing nearly theoretical sensitivity to pH can be fabricated by this process. A hybrid electrode structure permits the incorporation of a source follower FET amplifier directly adjacent to the pH membrane, significantly reducing response time and noise pick-up. Extension of the basic electrode structure to accommodate membranes sensitive to other ions is discussed.

摘要

我们报告了通过厚膜筛选技术制造适用于体内使用的pH敏感电极的实验初步结果。我们的结果表明,通过该工艺可以制造出具有合适厚度且对pH具有近乎理论灵敏度的玻璃膜。一种混合电极结构允许将源极跟随器场效应管放大器直接置于pH膜附近,显著缩短了响应时间并减少了噪声拾取。本文还讨论了如何扩展基本电极结构以适应对其他离子敏感的膜。