Abstract

The skulls of 46 patients were examined by means of ordinary scans and after contrast. 24 of these patients with cerebral abnormalities had scans, using identical planes, with and without contrast and with CPMG sequences. Contrast in intracranial, but extracerebral (extra-axial), tumours (meningiomas, neurinomas) was much better after using contrast, but intracerebral (intra-axial) tumours were mostly shown as well on T2-rated CPMG sequences. Image synthesis has shown that contrast uptake occurred only in solid tumour regions.

摘要

对46例患者的颅骨进行了普通扫描及增强扫描。其中24例有脑部异常的患者,使用相同层面进行了平扫、增强扫描以及CPMG序列扫描。颅内但脑外(轴外)肿瘤(脑膜瘤、神经鞘瘤)增强后的显影要好得多,但脑内(轴内)肿瘤在T2加权CPMG序列上大多也能很好地显示。图像合成显示,造影剂仅在实体瘤区域摄取。