Suppr超能文献

与使用液相色谱/串联质谱法分析血清相比,利用在线超临界流体萃取-超临界流体色谱/串联质谱法分析干血斑中的疾病生物标志物。

Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

作者信息

Suzuki Makoto, Nishiumi Shin, Kobayashi Takashi, Sakai Arata, Iwata Yosuke, Uchikata Takato, Izumi Yoshihiro, Azuma Takeshi, Bamba Takeshi, Yoshida Masaru

机构信息

Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017, Japan.

Shimadzu Corporation, 1 Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan.

出版信息

Rapid Commun Mass Spectrom. 2017 May 30;31(10):886-894. doi: 10.1002/rcm.7857.

Abstract

RATIONALE

The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS.

METHODS

The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS.

RESULTS

By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer.

CONCLUSIONS

The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd.

摘要

原理

基于干血斑(DSS)的生物标志物检测的分析稳定性和通量在很大程度上取决于提取过程和测定方法。在本研究中,建立了一种基于超临界流体萃取-超临界流体色谱联用串联质谱(SFE-SFC/MS/MS)的在线系统,用于分析DSS中疾病生物标志物的水平。

方法

使用ODS-EP、二醇和SIL-100A柱研究色谱条件。然后,我们使用二醇柱优化了SFE-SFC/MS/MS方法,重点关注使用液相色谱(LC)/MS/MS鉴定的口腔癌、结直肠癌和胰腺癌的候选生物标志物。

结果

通过使用该系统,在15分钟内同时检测到4种亲水性代谢物和17种疏水性代谢物。在一项涉及临床样本的实验中,PC 16:0-18:2/16:1-18:1检测口腔癌的灵敏度为93.8%,特异性为64.3%,而PC 17:1-18:1/17:0-18:2的灵敏度为81.3%,特异性为92.9%。此外,肌酸水平评估显示检测结直肠癌的灵敏度为92.3%,特异性为78.6%。

结论

本研究结果表明,我们的方法在临床诊断方面具有巨大潜力,适用于大规模筛查。版权所有© 2017约翰威立父子有限公司。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验