The goal was to determine the effect of cataract surgery-induced change in ametropia and anterior chamber depth on the magnification of a fundus photograph.
Fundus photographs were taken from 11 subjects undergoing cataract surgery and intraocular lens (IOL) implantation before and after surgery with a telecentric Zeiss and Topcon fundus cameras. The distance between two distinct fundus landmarks, i.e. two crossings of retinal vessels, was measured before and after surgery, and the results were compared to axial length and surgery-induced change in ametropia and anterior chamber depth. In addition, the change in the conversion factor of Topcon fundus camera was calculated and its correlation to axial length, change in ametropia and anterior chamber depth was analysed. Further, the change in the mathematical location of P', i.e. the second principal point of the eye in the formula of Bennett et al. (1994), was calculated.
Cataract surgery and IOL implantation did not significantly influence the magnification of a fundus photograph taken with a telecentric Zeiss or Topcon fundus camera even when ametropia changed markedly. Axial length and anterior chamber depth did not correlate with change in the magnification of a fundus photograph. The average change in the mathematical location P' due to surgery was -39.4%, SD 0.33.
Fundus photographs taken with a telecentric Zeiss or Topcon fundus camera can be reliably used to follow the size of fundus landmarks even if ametropia and anterior chamber depth are changed after cataract surgery and IOL implantation.
本研究旨在确定白内障手术引起的屈光不正和前房深度变化对眼底照片放大率的影响。
使用远心蔡司和拓普康眼底相机,对11例接受白内障手术和人工晶状体(IOL)植入的患者在手术前后拍摄眼底照片。测量手术前后两个不同眼底标志(即视网膜血管的两个交叉点)之间的距离,并将结果与眼轴长度、手术引起的屈光不正和前房深度变化进行比较。此外,计算拓普康眼底相机转换因子的变化,并分析其与眼轴长度、屈光不正变化和前房深度的相关性。进一步计算P'(即Bennett等人(1994年)公式中眼睛的第二主点)的数学位置变化。
即使屈光不正发生显著变化,白内障手术和IOL植入对使用远心蔡司或拓普康眼底相机拍摄的眼底照片放大率也没有显著影响。眼轴长度和前房深度与眼底照片放大率的变化无关。手术导致的数学位置P'的平均变化为-39.4%,标准差为0.33。
即使白内障手术和IOL植入后屈光不正和前房深度发生变化,使用远心蔡司或拓普康眼底相机拍摄的眼底照片也可可靠地用于跟踪眼底标志的大小。