Suppr超能文献

通过手动膜片钳和多电极阵列系统评估暴露于二甲基亚砜和乙醇的人诱导多能干细胞衍生心肌细胞中的电生理活性。

The assessment of electrophysiological activity in human-induced pluripotent stem cell-derived cardiomyocytes exposed to dimethyl sulfoxide and ethanol by manual patch clamp and multi-electrode array system.

作者信息

Hyun Soo-Wang, Kim Bo-Ram, Hyun Sung-Ae, Seo Joung-Wook

机构信息

Research Group for Safety Pharmacology, Korea Institute of Toxicology, KRICT, 34114 Daejeon, Republic of Korea.

出版信息

J Pharmacol Toxicol Methods. 2017 Sep;87:93-98. doi: 10.1016/j.vascn.2017.03.003. Epub 2017 Apr 2.

Abstract

INTRODUCTION

Recently, electrophysiological activity has been effectively measured in human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) to predict drug-induced arrhythmia. Dimethyl sulfoxide (DMSO) and ethanol have been used as diluting agents in many experiments. However, the maximum DMSO and ethanol concentrations that can be effectively used in the measurement of electrophysiological parameters in hiPSC-CMs-based patch clamp and multi-electrode array (MEA) have not been fully elucidated.

METHODS

We investigated the effects of varying concentrations of DMSO and ethanol used as diluting agents on several electrophysiological parameters in hiPSC-CMs using patch clamp and MEA.

RESULTS

Both DMSO and ethanol at concentrations>1% in external solution resulted in osmolality >400mOsmol/kg, but pH was not affected by either agent. Neither DMSO nor ethanol led to cell death at the concentrations examined. However, resting membrane potential, action potential amplitude, action potential duration at 90% and 40%, and corrected field potential duration were decreased significantly at 1% ethanol concentration. DMSO at 1% also significantly decreased the sodium spike amplitude. In addition, the waveform of action potential and field potential was recorded as irregular at 3% concentrations of both DMSO and ethanol. Concentrations of up to 0.3% of either agent did not affect osmolality, pH, cell death, or electrophysiological parameters in hiPSC-CMs.

DISCUSSION

Our findings suggest that 0.3% is the maximum concentration at which DMSO or ethanol should be used for dilution purposes in hiPSC-CMs-based patch clamp and MEA.

摘要

引言

最近,已能在人诱导多能干细胞衍生的心肌细胞(hiPSC-CMs)中有效测量电生理活性,以预测药物诱发的心律失常。在许多实验中,二甲基亚砜(DMSO)和乙醇已被用作稀释剂。然而,在基于hiPSC-CMs的膜片钳和多电极阵列(MEA)中,可有效用于测量电生理参数的DMSO和乙醇的最大浓度尚未完全阐明。

方法

我们使用膜片钳和MEA研究了不同浓度的DMSO和乙醇作为稀释剂对hiPSC-CMs中几种电生理参数的影响。

结果

外部溶液中浓度>1%的DMSO和乙醇均导致渗透压>400mOsmol/kg,但pH值不受任何一种试剂影响。在所检测的浓度下,DMSO和乙醇均未导致细胞死亡。然而,在1%乙醇浓度下,静息膜电位、动作电位幅度、90%和40%动作电位持续时间以及校正场电位持续时间均显著降低。1%的DMSO也显著降低了钠峰幅度。此外,在3%的DMSO和乙醇浓度下,动作电位和场电位的波形记录为不规则。两种试剂浓度高达0.3%时,均不影响hiPSC-CMs中的渗透压、pH值、细胞死亡或电生理参数。

讨论

我们的研究结果表明,在基于hiPSC-CMs的膜片钳和MEA中,0.3%是DMSO或乙醇用于稀释目的的最大浓度。