van Kesteren F, Elattar M A, van Lienden K P, Baan J, Marquering H A, Planken R N
Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam, The Netherlands; Heart Centre, Academic Medical Centre, Amsterdam, The Netherlands.
Department of Biomedical Engineering and Physics, Academic Medical Centre, Amsterdam, The Netherlands.
Clin Radiol. 2017 Aug;72(8):695.e1-695.e6. doi: 10.1016/j.crad.2017.03.003. Epub 2017 Apr 4.
To compare the objective and subjective image quality of non-contrast three-dimensional (3D) navigator-gated balanced steady state free precession magnetic resonance angiography (NC-MRA) and contrast-enhanced magnetic resonance angiography (CE-MRA) along the entire thoracic aorta.
Fifty consecutive patients with thoracic aortic disease underwent NC-MRA and CE-MRA using a 1.5 T MRI system. Vessel sharpness was assessed using signal intensity profiles at five predefined levels of the thoracic aorta. Two readers scored subjective quality. Manual diameter measurements of both readers were used for calculation of interobserver variation.
NC-MRA resulted in significantly sharper delineation of the aortic root, ascending aorta, and distal descending aorta compared to CE-MRA. Sharpness was comparable at the level of the arch and proximal descending aorta. NC-MRA resulted in significantly better subjective image quality. Interobserver agreement for diameter measurements was excellent for both techniques.
NC-MRA resulted in superior image quality for assessment of the thoracic aorta and in better vessel sharpness for assessment of the aortic root and ascending aorta, when compared to CE-MRA. NC-MRA can be considered the MRA technique of choice for the assessment of the thoracic aorta diameters in clinical practice.
比较非对比剂三维(3D)导航门控稳态自由进动磁共振血管造影(NC-MRA)和对比增强磁共振血管造影(CE-MRA)在整个胸主动脉的客观和主观图像质量。
连续50例胸主动脉疾病患者使用1.5 T MRI系统接受NC-MRA和CE-MRA检查。在胸主动脉五个预定义水平处使用信号强度剖面图评估血管清晰度。两名阅片者对主观质量进行评分。两名阅片者的手动直径测量用于计算观察者间差异。
与CE-MRA相比,NC-MRA对主动脉根部、升主动脉和降主动脉远端的描绘明显更清晰。在主动脉弓和降主动脉近端水平,清晰度相当。NC-MRA的主观图像质量明显更好。两种技术在直径测量方面观察者间的一致性都很好。
与CE-MRA相比,NC-MRA在评估胸主动脉时图像质量更佳,在评估主动脉根部和升主动脉时血管清晰度更高。在临床实践中,NC-MRA可被视为评估胸主动脉直径的首选MRA技术。