Suppr超能文献

电击频率和电流波形对禽类福利和肉质的影响。

Effect of electrical stunning frequency and current waveform in poultry welfare and meat quality.

出版信息

Poult Sci. 2017 Aug 1;96(8):2956-2964. doi: 10.3382/ps/pex046.

Abstract

This study aimed to evaluate the effects of different stunning frequencies and electrical current waveforms on chicken welfare and meat quality. Two-hundred-thirty-two Cobb broilers, 48 d of age and 2.76 ± 0.47 live-weight, were randomly assigned into 4 stunning treatments - 2 frequencies (300 Hz and 650 Hz) and 2 current waveforms (direct current [DC] and alternating current [AC]). Broilers were electrically stunned in a water bath in a commercial slaughterhouse (70 V, 100 mA). The electronarcosis and stunning efficiency were confirmed by assessment of visual parameters (absence of rhythmic breathing, ocular reflex, and coordinated wing flapping) and blood parameters (lactate, glucose, creatine kinase, sodium, and potassium), which were measured after bleeding. The incidence of traumas and injuries was assessed after plucking. Meat quality analysis was performed in Pectoralis major (PM), with determinations of pH, breast yield (PMY), water holding capacity (WHC), water absorption capacity (WAC), thawing loss (DL), cooking loss (CL), shear force (SF), and instrumental color (a*, b*, L*, C*, and h). The interaction between waveform and frequency was significant (P < 0.05) only for lactate, sodium, and lightness (L*). Lactate and sodium levels decreased at 300 Hz-DC. Meat lightness increased at 300 Hz-DC. The individual effect of frequency was significant for glucose, creatine kinase, potassium, WHC, PMY, b*, C*, and h. Regarding waveform, AC decreased plasma glucose and DC decreased creatine kinase and WAC. In general, stunning frequency exerts greater influence than waveform on the welfare and meat quality parameters of broilers. The use of frequency at 650 Hz proved to render animals efficiently unconscious and to promote greater meat quality.

摘要

本研究旨在评估不同的电击频率和电流波形对鸡肉福利和肉质的影响。将 232 只 48 日龄、体重为 2.76±0.47 千克的科宝肉鸡随机分为 4 种电击处理组 - 2 种频率(300Hz 和 650Hz)和 2 种电流波形(直流电[DC]和交流电[AC])。肉鸡在商业屠宰场的水浴中进行电击,使用 70V、100mA 的电击强度。通过评估视觉参数(无节律性呼吸、眼球反射和协调的翅膀拍打)和血液参数(乳酸、葡萄糖、肌酸激酶、钠和钾)来确认电子麻醉和电击效率,这些参数在放血后进行测量。在拔毛后评估创伤和损伤的发生率。在胸大肌(PM)中进行肉质分析,测定 pH 值、胸肉产量(PMY)、水分保持能力(WHC)、水分吸收能力(WAC)、解冻损失(DL)、烹饪损失(CL)、剪切力(SF)和仪器颜色(a*、b*、L*、C和 h)。仅在乳酸、钠和亮度(L)方面,波形和频率之间存在显著的交互作用(P<0.05)。在 300Hz-DC 时,乳酸和钠水平降低。在 300Hz-DC 时,肉的亮度增加。频率的单独影响在葡萄糖、肌酸激酶、钾、WHC、PMY、b*、C*和 h 方面显著。关于波形,交流电降低了血浆葡萄糖,直流电降低了肌酸激酶和 WAC。总的来说,电击频率对肉鸡的福利和肉质参数的影响大于波形。使用 650Hz 的频率被证明能使动物有效地失去意识,并提高肉质。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验