桡骨头植入物形状对桡骨小头关节匹配度的影响。

Effect of Radial Head Implant Shape on Radiocapitellar Joint Congruency.

作者信息

Lalone Emily A, Shannon Hannah L, Deluce Simon R, Giles Joshua W, King Graham J W, Johnson James A

机构信息

Bioengineering Laboratory, Roth McFarlane Hand and Upper Limb Centre, St Joseph's Hospital, London, Canada.

Bioengineering Laboratory, Roth McFarlane Hand and Upper Limb Centre, St Joseph's Hospital, London, Canada; Department of Surgery, University of Western Ontario, London, Canada.

出版信息

J Hand Surg Am. 2017 Jun;42(6):476.e1-476.e11. doi: 10.1016/j.jhsa.2017.03.009. Epub 2017 Apr 25.

Abstract

PURPOSE

Radial head arthroplasty is indicated in displaced fractures in which comminution precludes successful internal fixation. Many types of radial head implants have been developed varying in material, methods of fixation, and degrees of modularity and geometry. The purpose of this study was to investigate the effect of radial head implant shape on radiocapitellar joint congruency.

METHODS

Joint congruency was quantified in 7 cadaveric specimens employing a registration and inter-surface distance algorithm and 3-dimensional models obtained using computed tomography. Forearm rotation was simulated after computer-guided implantation of an axisymmetric radial head, a population-based quasi-anatomic radial head implant, and a reverse-engineered anatomic radial head implant. Inter-surface distances were measured to investigate the relative position of the radial head implant and displayed on 3-dimensional color-contour maps. Surface area was measured for inter-surface distances (1.5 mm) and compared for each radial head geometry.

RESULTS

There were no statistical differences in the contact surface area between radial head implants during active or passive forearm rotation. The joint was more congruent (larger contact surface area) during active forearm rotation compared with passive forearm rotation.

CONCLUSIONS

This study investigated the effect of implant geometry on the radiocapitellar joint contact mechanics by examining a commercially available radial head system (axisymmetric), a quasi-anatomic design, and an anatomic reverse-engineered radial head implant. We found no statistical differences in radiocapitellar joint contact mechanics as measured by 3-dimensional joint congruency in cadaveric specimens undergoing continuous simulated forearm rotation.

CLINICAL RELEVANCE

The importance of choosing an implant that matches the general size of the native radial head is recognized, but the degree to which it is necessary to create an implant that replicates the native anatomy to restore elbow stability and prevent cartilage degenerative changes remains unclear. This study concluded that the geometry of the implant did not have a statistically significant effect on joint contact mechanics; therefore, future work is needed to examine additional factors related to implant design, such as material choice and implant positioning to investigate their influence on joint contact mechanics.

摘要

目的

对于粉碎性骨折导致无法成功进行内固定的移位骨折,需行桡骨头置换术。目前已研发出多种类型的桡骨头植入物,其在材料、固定方法、模块化程度和几何形状等方面存在差异。本研究旨在探讨桡骨头植入物形状对桡肱关节匹配度的影响。

方法

采用配准和表面间距离算法以及计算机断层扫描获得的三维模型,对7具尸体标本的关节匹配度进行量化。在计算机引导下植入轴对称桡骨头、基于群体的准解剖型桡骨头植入物和逆向工程解剖型桡骨头植入物后,模拟前臂旋转。测量表面间距离以研究桡骨头植入物的相对位置,并显示在三维彩色等高线图上。测量表面间距离为1.5毫米时的表面积,并对每种桡骨头几何形状进行比较。

结果

在前臂主动或被动旋转过程中,桡骨头植入物之间的接触表面积无统计学差异。与被动前臂旋转相比,主动前臂旋转时关节匹配度更高(接触表面积更大)。

结论

本研究通过检查市售桡骨头系统(轴对称)、准解剖设计和解剖逆向工程桡骨头植入物,探讨了植入物几何形状对桡肱关节接触力学的影响。我们发现,在连续模拟前臂旋转的尸体标本中,通过三维关节匹配度测量的桡肱关节接触力学无统计学差异。

临床意义

人们认识到选择与天然桡骨头总体尺寸相匹配的植入物的重要性,但对于制造复制天然解剖结构以恢复肘关节稳定性并防止软骨退变的植入物的必要性程度仍不清楚。本研究得出结论,植入物的几何形状对关节接触力学没有统计学上的显著影响;因此,未来需要开展工作来研究与植入物设计相关的其他因素,如材料选择和植入物定位,以探讨它们对关节接触力学的影响。