Suppr超能文献

电极放置位置是否会影响实验性炎症痛模型中经皮电神经刺激的抗痛觉过敏作用?

Does electrode placement influence tens-induced antihyperalgesia in experimental inflammatory pain model?

机构信息

Programa de Pós-graduação em Ciências da Saúde, Universidade Federal de Sergipe (UFS), Aracaju, SE, Brazil.

Departamento de Fisioterapia, Universidade Federal de Sergipe (UFS), Aracaju, SE, Brazil.

出版信息

Braz J Phys Ther. 2017 Mar-Apr;21(2):92-99. doi: 10.1016/j.bjpt.2017.03.003. Epub 2017 Mar 17.

Abstract

BACKGROUND

Transcutaneous electrical nerve stimulation (TENS) is a treatment commonly used for managing pain; however, the ideal placement of the electrodes is not fully understood.

OBJECTIVE

To investigate the best way to apply TENS electrodes in an experimental inflammatory pain model.

METHOD

Knee joint inflammation was induced in rats, followed by administration of low-frequency TENS (4Hz) under anesthesia for five days. Animals were randomly allocated to five groups according to electrode placement (n=6, each): dermatome, contralateral, paraspinal, acupoint, and control.

INTERVENTIONS

Low-frequency TENS at sensory intensity and 100μs pulse duration. Withdrawal thresholds to mechanical (von Frey) and thermal stimuli and joint edema were assessed before induction of inflammation and immediately before and after application of TENS.

RESULTS

Reduced paw withdrawal threshold and thermal latency that occur 24h after the induction of inflammation were significantly reversed by the administration of TENS in all groups when compared with sham treatment or with the condition before TENS treatment. No difference was observed in the edema measurement.

CONCLUSION

These results offer more options for practitioners to choose the area of the body most commodious for electrode placement, depending on the clinical condition of the patient, because the effect was similar at all sites. In addition, there was a loss of the effectiveness of TENS in reversing mechanical and thermal hyperalgesia on the fifth day, suggesting the development of the tolerance phenomenon.

摘要

背景

经皮神经电刺激(TENS)是一种常用于治疗疼痛的方法;然而,电极的最佳放置位置尚不完全清楚。

目的

研究在实验性炎症痛模型中 TENS 电极的最佳应用方法。

方法

在大鼠膝关节诱导炎症,然后在麻醉下给予低频 TENS(4Hz)连续 5 天。动物根据电极放置位置随机分为 5 组(每组 6 只):皮节、对侧、椎旁、穴位和对照。

干预

感觉强度和 100μs 脉冲持续时间的低频 TENS。在炎症诱导前、TENS 治疗前和治疗后即刻评估机械(von Frey)和热刺激的撤回阈值以及关节肿胀。

结果

与假处理或 TENS 治疗前相比,所有组在炎症诱导后 24 小时给予 TENS 治疗可显著逆转足部撤回阈值和热潜伏期的降低。在肿胀测量方面没有差异。

结论

这些结果为从业者提供了更多选择,可根据患者的临床情况选择最方便的身体部位放置电极,因为所有部位的效果相似。此外,在第 5 天,TENS 缓解机械和热痛觉过敏的效果丧失,表明出现了耐受现象。