Özgen Burçe, Bulut Elif, Dolgun Anıl, Bajin Munir Demir, Sennaroğlu Levent
Department of Radiology, Hacettepe University School of Medicine, Ankara, Turkey.
Diagn Interv Radiol. 2017 Jul-Aug;23(4):300-306. doi: 10.5152/dir.2017.16024.
We aimed to evaluate the diagnostic accuracy of turbo spin-echo diffusion-weighted imaging (TSE-DWI) at 3 T, for cholesteatoma (CS) diagnosis, using qualitative and quantitative methods with numerical assessment of signal intensity (SI), signal intensity ratios (SIR), and apparent diffusion coefficient (ADC) values.
In this retrospective study, two blinded observers independently evaluated the preoperative TSE-DWI images of 57 patients who were imaged with a presumed diagnosis of CS. Qualitative assessment with respect to the SI of the adjacent cortex and quantitative measurements of SI, SIR, and ADC values were performed.
Surgery with histopathologic examination revealed 30 CS patients and 27 patients with non-cholesteatoma (NCS) lesions including chronic inflammation and cholesterol granuloma. On TSE-DWI, 96.7% of the CS lesions and none of the NCS lesions appeared hyperintense compared with the cortex. The mean SI and SIR indices of the CS group were significantly higher and the mean ADC values significantly lower compared with those of the NCS group (P < 0.001). Using specific cutoff values for SI (92.5) and SIR (0.9), CS could be diagnosed with 100% sensitivity and specificity. The use of quantitative imaging further increased the sensitivity of the TSE-DWI technique.
The quantitative indices of SI, SIR, and ADC of TSE-DWI appear to be highly accurate parameters that can be used to confirm the diagnosis of CS.
我们旨在评估3T场强下的涡轮自旋回波扩散加权成像(TSE-DWI)对胆脂瘤(CS)诊断的准确性,采用定性和定量方法,对信号强度(SI)、信号强度比(SIR)和表观扩散系数(ADC)值进行数值评估。
在这项回顾性研究中,两名盲法观察者独立评估了57例疑似CS患者的术前TSE-DWI图像。对相邻皮质的SI进行定性评估,并对SI、SIR和ADC值进行定量测量。
组织病理学检查的手术结果显示,有30例CS患者和27例非胆脂瘤(NCS)病变患者,后者包括慢性炎症和胆固醇肉芽肿。在TSE-DWI上,与皮质相比,96.7%的CS病变呈高信号,而NCS病变均未呈高信号。与NCS组相比,CS组的平均SI和SIR指数显著更高,平均ADC值显著更低(P < 0.001)。使用SI(92.5)和SIR(0.9)的特定临界值,可以100%的敏感性和特异性诊断CS。定量成像的应用进一步提高了TSE-DWI技术的敏感性。
TSE-DWI的SI、SIR和ADC定量指标似乎是可用于确诊CS的高度准确的参数。