Shaygi Behnam, Kinsella Denis, Watkinson Anthony F
Department of Interventional Radiology, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK.
Department of Interventional Radiology, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK.
Ann Vasc Surg. 2017 Aug;43:311.e5-311.e7. doi: 10.1016/j.avsg.2017.02.011. Epub 2017 May 4.
We report the case of a 74-year-old male with an incidental finding of a pseudoaneurysm at the base of his neck arising from the left subclavian artery. Initial treatment with ultrasound-guided thrombin injection was unfortunately unsuccessful with early recanalization. An Amplatzer Vascular Plug 4 device was introduced into the neck of the pseudoaneurysm endovascularly with successful thrombosis and occlusion of the pseudoaneurysm.
我们报告了一例74岁男性病例,其颈部根部意外发现一个源自左锁骨下动脉的假性动脉瘤。不幸的是,最初采用超声引导下注射凝血酶治疗未成功,假性动脉瘤早期再通。通过血管腔内介入将一个Amplatzer血管封堵器4置入假性动脉瘤颈部,成功实现了假性动脉瘤的血栓形成和闭塞。