Megahed Ameer A, Hiew Mark W H, Townsend Jonathan R, Constable Peter D
Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, USA.
Department of Animal Medicine (Internal Medicine), Faculty of Veterinary Medicine, Benha University, Benha, Egypt.
Vet Clin Pathol. 2017 Jun;46(2):314-325. doi: 10.1111/vcp.12493. Epub 2017 May 9.
The Precision Xtra electrochemical meter is widely used to measure blood β-hydroxybutyrate concentration (BHBb) in dairy cattle. The meter uses an algorithm optimized for human blood that assumes the HCT in cattle is the same as in people, and that intra-erythrocyte β-hydroxybutyrate (BHBe) and plasma β-hydroxybutyrate (BHBp) concentration are equivalent.
The first objective was to characterize the analytic performance of the meter for measuring BHBb and BHBp in dairy cattle. The second objective was to characterize the influence of HCT and sample temperature on BHBp concentration measured by the meter.
Blood and plasma samples were obtained from 106 periparturient Holstein cattle and 15 lactating Holstein cows with experimentally induced electrolyte and acid-base imbalances. Meter performance was evaluated using Deming regression and Bland-Altman plots. Multivariable linear regression was used to determine the effect of HCT and sample temperature on BHBb and BHBp concentration, respectively.
The meter was linear up to BHB = 3.0 mmol/L as measured by the reference method, equivalent to meter values for BHBb > 4.5 mmol/L and BHBp > 5.2 mmol/L. An increase in HCT resulted in higher BHBb concentration. This result was partially explained by BHBe being much lower than BHBp. Changes in sample temperature caused a linear change in measured BHBp whenever BHBp > 3.0 mmol/L.
Meter accuracy was markedly dependent on the BHBe-to-BHBp ratio and consequently the HCT. Therefore, the algorithm used by the meter should be revised when applied to bovine blood for improved accuracy.
Precision Xtra电化学血糖仪被广泛用于测量奶牛血液中的β-羟基丁酸浓度(BHBb)。该血糖仪使用针对人体血液优化的算法,该算法假定牛的血细胞比容(HCT)与人类相同,并且红细胞内β-羟基丁酸(BHBe)和血浆β-羟基丁酸(BHBp)浓度相等。
第一个目的是表征该血糖仪测量奶牛BHBb和BHBp的分析性能。第二个目的是表征HCT和样品温度对该血糖仪测量的BHBp浓度的影响。
从106头围产期荷斯坦奶牛和15头患有实验性诱导的电解质和酸碱失衡的泌乳荷斯坦奶牛中采集血液和血浆样本。使用Deming回归和Bland-Altman图评估血糖仪性能。分别使用多变量线性回归来确定HCT和样品温度对BHBb和BHBp浓度的影响。
通过参考方法测量,该血糖仪在BHB = 3.0 mmol/L以下呈线性,相当于BHBb > 4.5 mmol/L和BHBp > 5.2 mmol/L时的血糖仪值。HCT的增加导致BHBb浓度升高。这一结果部分是由于BHBe远低于BHBp。每当BHBp > 3.0 mmol/L时,样品温度的变化会导致测量的BHBp呈线性变化。
血糖仪的准确性明显取决于BHBe与BHBp的比率,因此也取决于HCT。因此,当将该血糖仪使用的算法应用于牛血液时,应进行修订以提高准确性。