Bożek Agnieszka, Reich Adam
Department of Dermatology, Venereology and Allergology, Wrocław Medical University, Wrocław, Poland.
Dermatology. 2017;233(1):16-22. doi: 10.1159/000472711. Epub 2017 May 12.
Numerous different scoring systems have been proposed for assessing the severity of atopic dermatitis (AD). Many of these methods did not undergo proper validation and reliability testing.
The aim of our study was to compare the reliability and reproducibility of the Eczema Area and Severity Index (EASI), objective Scoring Atopic Dermatitis (oSCORAD), and Investigator Global Assessment (IGA).
On the scoring day, 10 trained dermatologists evaluated 10 adult patients with AD using the EASI, oSCORAD, and IGA. All subjects were assessed twice by each physician. Correlations between measures were analysed using the Pearson correlation coefficient. The intra-class correlation coefficient (ICC) was calculated to assess intra-rater reliability; the coefficient of variation (CV) was used to assess inter-rater variability.
Significant positive correlations were observed between each scale in both assessments. The ICCs for the EASI and oSCORAD were 0.71 and 0.66, respectively, indicating good reliability, while the ICC for the IGA (0.54) indicated only fair reliability. The CVs for the oSCORAD and IGA were 28.1 and 33.0, respectively, indicating moderate variability. The CV for the EASI was 66.5, indicating high variability.
Among the 3 compared scales, the oSCORAD had the highest inter-rater reliability, whereas the EASI had the highest intra-rater reliability. None of the 3 scoring methods showed a significant advantage over the other. Thus, a reliable assessment of AD severity requires the use of at least 2 independent measurements simultaneously.
已经提出了许多不同的评分系统来评估特应性皮炎(AD)的严重程度。其中许多方法未经过适当的验证和可靠性测试。
我们研究的目的是比较湿疹面积和严重程度指数(EASI)、客观特应性皮炎评分(oSCORAD)和研究者整体评估(IGA)的可靠性和可重复性。
在评分日,10名经过培训的皮肤科医生使用EASI、oSCORAD和IGA对10名成年AD患者进行评估。每位医生对所有受试者进行两次评估。使用Pearson相关系数分析测量值之间的相关性。计算组内相关系数(ICC)以评估评分者内可靠性;变异系数(CV)用于评估评分者间变异性。
在两次评估中,各量表之间均观察到显著的正相关。EASI和oSCORAD的ICC分别为0.71和0.66,表明可靠性良好,而IGA的ICC(0.54)仅表明可靠性一般。oSCORAD和IGA的CV分别为28.1和33.0,表明变异性中等。EASI的CV为66.5,表明变异性高。
在比较的3个量表中,oSCORAD具有最高的评分者间可靠性,而EASI具有最高的评分者内可靠性。这3种评分方法均未显示出相对于其他方法的显著优势。因此,对AD严重程度进行可靠评估需要同时使用至少2种独立测量方法。