Champaneri Bhavik, Kappanayil Mahesh, Kumar Raman K
Department of Pediatric Cardiology,Amrita Institute of Medical Sciences,Kochi,Kerala,India.
Cardiol Young. 2017 Sep;27(7):1437-1440. doi: 10.1017/S1047951117000695. Epub 2017 May 16.
Catheter closure of membranous ventricular septal defects is generally not considered feasible in small infants. We report the successful closure of a membranous ventricular septal defect in a 1.8-kg infant with bilateral femoral artery occlusion using Amplatzer Duct Occluder II additional size device. The ventricular septal defect was crossed from the right ventricle, and the device was deployed using transthoracic echocardiographic guidance.
在小婴儿中,经导管闭合膜周部室间隔缺损通常被认为不可行。我们报告了使用Amplatzer II型动脉导管封堵器额外尺寸装置成功闭合一名体重1.8千克、双侧股动脉闭塞婴儿的膜周部室间隔缺损。室间隔缺损从右心室穿过,在经胸超声心动图引导下置入该装置。