A novel method for measuring subcutaneous adipose tissue using ultrasound in children - interobserver consistency.

作者信息

ChiriŢă-Emandi Adela, Papa Maria Camelia, Abrudan Liliana, Dobrescu Mihaela Amelia, Puiu Maria, Velea Iulian Puiu, Paul Corina

机构信息

Department of Genetics, University of Medicine and Pharmacy of Craiova, Romania;

出版信息

Rom J Morphol Embryol. 2017;58(1):115-123.

Abstract

BACKGROUND

Currently, sufficiently accurate field methods for body composition assessment in children are missing. The ultrasound method for assessing adipose tissue thickness has been used extensively in sport medicine. However, there are no studies looking at the reliability of this method in non-athletic children. This paper aims to determine the inter-observer reliability in measuring the uncompressed subcutaneous adipose tissue thickness using ultrasound, in children.

SUBJECTS, MATERIALS AND METHODS: Forty healthy children (20 males, 20 females), median age 11.85 years (5.3 to 18.1 years) were evaluated. Median body mass index standard deviation score (BMI SDS) was -0.13 (-3.9 to 4). Three observers used a Hosand BX 2000 Ultrasonic Adipometer to measure uncompressed subcutaneous adipose tissue thickness at three sites: triceps, subscapular, supraspinale. A single experienced observer used the three sites to also measure the compressed adipose thickness using a skinfold caliper.

RESULTS

Individual observer deviations from the mean value of the three observers in adipometer measurement had a standard deviation of 1.74 mm, 92.8% were less than 3 mm. Analysis separated by individual anatomical sites showed high reliability values for triceps: linear regression R²=0.84, p=0.000; intraclass correlation coefficient (ICC)=0.92 and standard error of measurement (SEM)=0.63. The values at supraspinale site were R²=0.82, p=0.000, ICC=0.89 and SEM=1.17, while for subscapular the values were lower: R²=0.79, p=0.000, ICC=0.78 and SEM=1.02. The body fat percentage (BF%) calculated using skinfold measurements was highly correlated with the BF% calculated by the adipometer (R=0.92, R²=0.83, p=0.000). The Pearson's correlation between BMI SDS and BF% calculated from skinfold was R=0.52, R²=0.28, p=0.001, while for the adipometer it was R=0.53, R²=0.27, p=0.000.

CONCLUSIONS

This novel ultrasound measurement technique can be used with good accuracy and reliability to measure uncompressed subcutaneous adipose tissue thickness in children, sustaining its application for research and clinical purposes, however larger studies are needed.

摘要

背景

目前,尚缺乏足够准确的儿童身体成分评估现场方法。超声评估脂肪组织厚度的方法已在运动医学中广泛应用。然而,尚无研究探讨该方法在非运动员儿童中的可靠性。本文旨在确定使用超声测量儿童未压缩皮下脂肪组织厚度时观察者间的可靠性。

受试者、材料与方法:对40名健康儿童(20名男性,20名女性)进行评估,中位年龄11.85岁(5.3至18.1岁)。中位体重指数标准差评分(BMI SDS)为-0.13(-3.9至4)。三名观察者使用Hosand BX 2000超声脂肪测量仪在三个部位测量未压缩皮下脂肪组织厚度:肱三头肌、肩胛下、脊柱上。一名经验丰富的观察者也使用这三个部位,用皮褶厚度计测量压缩脂肪厚度。

结果

在脂肪测量仪测量中,个体观察者与三名观察者平均值的偏差标准差为1.74毫米,92.8%小于3毫米。按个体解剖部位分析显示,肱三头肌的可靠性值较高:线性回归R² = 0.84,p = 0.000;组内相关系数(ICC)= 0.92,测量标准误(SEM)= 0.63。脊柱上部位的值为R² = 0.82,p = 0.000,ICC = 0.89,SEM = 1.17,而肩胛下部位的值较低:R² = 0.79,p = 0.000,ICC = 0.78,SEM = 1.02。使用皮褶测量计算的体脂百分比(BF%)与脂肪测量仪计算的BF%高度相关(R = 0.92,R² = 0.83,p = 0.000)。BMI SDS与皮褶计算的BF%之间的Pearson相关性为R = 0.52,R² = 0.28,p = 0.001,而与脂肪测量仪计算的相关性为R = 0.53,R² = 0.27,p = 0.000。

结论

这种新型超声测量技术可用于准确可靠地测量儿童未压缩皮下脂肪组织厚度,支持其在研究和临床中的应用,不过还需要更大规模的研究。