Suppr超能文献

玻璃纤维网对具有模拟口腔黏膜的测试模型中的全口义齿的增强效果。

Reinforcing effect of glass-fiber mesh on complete dentures in a test model with a simulated oral mucosa.

机构信息

Postdoctoral Researcher, Department of Dental Biomaterials, College of Dentistry, Wonkwang University, Jeonbuk, Republic of Korea.

Associate Professor, Department of Dental Biomaterials and Institute of Biomaterials-Implant, College of Dentistry, Wonkwang University, Jeonbuk, Republic of Korea.

出版信息

J Prosthet Dent. 2017 Nov;118(5):650-657. doi: 10.1016/j.prosdent.2017.03.018. Epub 2017 May 23.

Abstract

STATEMENT OF PROBLEM

Studies that evaluated the strength of complete dentures reinforced with glass-fiber mesh or metal mesh on a cast with a simulated oral mucosa are lacking.

PURPOSE

The purpose of this in vitro study was to compare the mechanical properties of maxillary complete dentures reinforced with glass-fiber mesh with those of metal mesh in a new test model, using a simulated oral mucosa.

MATERIAL AND METHODS

Complete dentures reinforced with 2 types of glass-fiber mesh, SES mesh (SES) and glass cloth (GC) and metal mesh (metal) were fabricated. Complete dentures without any reinforcement were prepared as a control (n=10). The complete dentures were located on a cast with a simulated oral mucosa, and a load was applied on the posterior artificial teeth bilaterally. The fracture load, elastic modulus, and toughness of a complete denture were measured using a universal testing machine at a crosshead speed of 5 mm/min. The fracture load and elastic modulus were analyzed using 1-way analysis of variance, and the toughness was analyzed with the Kruskal-Wallis test (α=.05). The Tukey multiple range test was used as a post hoc test.

RESULTS

The fracture load and toughness of the SES group was significantly higher than that of the metal and control groups (P<.05) but not significantly different from that of the GC group. The elastic modulus of the metal group was significantly higher than that of the control group (P<.05), and no significant differences were observed in the SES and GC groups.

CONCLUSIONS

Compared with the control group, the fracture load and toughness of the SES and GC groups were higher, while those of the metal group were not significantly different.

摘要

问题陈述

缺乏评估带有模拟口腔黏膜的铸造体上用玻璃纤维网或金属网增强的全口义齿强度的研究。

目的

本体外研究的目的是在新的测试模型中使用模拟口腔黏膜比较玻璃纤维网增强上颌全口义齿的机械性能与金属网增强全口义齿的机械性能。

材料与方法

制作了两种类型的玻璃纤维网增强的全口义齿,SES 网(SES)和玻璃布(GC)以及金属网(金属)。制备了没有任何增强的全口义齿作为对照(n=10)。将全口义齿放置在带有模拟口腔黏膜的铸造体上,在双侧后人工牙上施加负载。使用万能试验机以 5mm/min 的十字头速度测量全口义齿的断裂载荷、弹性模量和韧性。使用单向方差分析分析断裂载荷和弹性模量,使用 Kruskal-Wallis 检验分析韧性(α=.05)。使用 Tukey 多重范围检验作为事后检验。

结果

SES 组的断裂载荷和韧性显著高于金属组和对照组(P<.05),但与 GC 组无显著差异。金属组的弹性模量显著高于对照组(P<.05),SES 组和 GC 组之间无显著差异。

结论

与对照组相比,SES 组和 GC 组的断裂载荷和韧性较高,而金属组的则没有显著差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验