一种基于固定在金电极上的血红蛋白纳米颗粒的安培型过氧化氢生物传感器。

An amperometric HO biosensor based on hemoglobin nanoparticles immobilized on to a gold electrode.

作者信息

Narwal Vinay, Yadav Neelam, Thakur Manisha, Pundir Chandra S

机构信息

Department of Biochemistry, M.D. University, Rohtak, Haryana, India.

Centre for Biotechnology, M.D. University, Rohtak, Haryana, India.

出版信息

Biosci Rep. 2017 Jul 16;37(4). doi: 10.1042/BSR20170194. Print 2017 Aug 31.

Abstract

The nanoparticles (NPs) of hemoglobin (Hb) were prepared by desolvation method and characterized by transmission electron microscopy (TEM), UV spectroscopy and Fourier-transform IR (FTIR) spectroscopy. An amperometric HO biosensor was constructed by immobilizing HbNPs covalently on to a polycrystalline Au electrode (AuE). HbNPs/AuE were characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectra (EIS) before and after immobilization of HbNPs. The HbNPs/AuE showed optimum response within 2.5 s at pH 6.5 in 0.1 M sodium phosphate buffer (PB) containing 100 μM HO at 30°C, when operated at -0.2 V against Ag/AgCl. The HbNPs/AuE exhibited of 5.161 ± 0.1 μA cm with apparent Michaelis-Menten constant () of 0.1 ± 0.01 mM. The biosensor showed lower detection limit (1.0 μM), high sensitivity (129 ± 0.25 μA cm mM) and wider linear range (1.0-1200 μM) for HO as compared with earlier biosensors. The analytical recoveries of added HO in serum (0.5 and 1.0 μM) were 97.77 and 98.01% respectively, within and between batch coefficients of variation (CV) were 3.16 and 3.36% respectively. There was a good correlation between sera HO values obtained by standard enzymic colorimetric method and the present biosensor (correlation coefficient, =0.99). The biosensor measured HO level in sera of apparently healthy subjects and persons suffering from diabetes type II. The HbNPs/AuE lost 10% of its initial activity after 90 days of regular use, when stored dry at 4°C.

摘要

采用去溶剂法制备了血红蛋白(Hb)纳米颗粒(NPs),并通过透射电子显微镜(TEM)、紫外光谱和傅里叶变换红外(FTIR)光谱对其进行了表征。通过将HbNPs共价固定在多晶金电极(AuE)上构建了一种安培型HO生物传感器。在固定HbNPs前后,通过扫描电子显微镜(SEM)、循环伏安法(CV)和电化学阻抗谱(EIS)对HbNPs/AuE进行了表征。当在相对于Ag/AgCl为-0.2 V的条件下操作时,HbNPs/AuE在30°C下于含100μM HO的0.1 M磷酸钠缓冲液(PB)中,在pH 6.5时2.5 s内显示出最佳响应。HbNPs/AuE的灵敏度为5.161±0.1μA cm,表观米氏常数()为0.1±0.01 mM。与早期的生物传感器相比,该生物传感器对HO的检测限更低(1.0μM)、灵敏度更高(129±0.25μA cm mM)且线性范围更宽(1.0 - 1200μM)。血清中添加的HO(0.5和1.0μM)的分析回收率分别为97.77%和98.01%,批内和批间变异系数(CV)分别为3.16%和3.36%。通过标准酶比色法获得的血清HO值与本生物传感器之间具有良好的相关性(相关系数,=0.99)。该生物传感器测量了明显健康的受试者和II型糖尿病患者血清中的HO水平。当在4°C下干燥保存时,HbNPs/AuE在正常使用90天后失去了其初始活性的10%。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e155/5518533/f9d93dcb30ec/bsr-37-bsr20170194-g1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验