Private Practice, Sassuolo, MO, 41049, Italy.
Private Practice, Terranegra di Legnago, VR, 37045, Italy.
Clin Implant Dent Relat Res. 2017 Aug;19(4):663-670. doi: 10.1111/cid.12504. Epub 2017 May 29.
Human studies on implants with the same design but with different surfaces are lacking at the present time.
The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully "sandblasted and double-etched" (SDE) implants and hybrid (H) implants, with an apical SDE-surface and a coronal machined-surface.
The SDE- and H-surfaces were previously analyzed under SEM and profilometer. Implants were placed in partially edentulous periodontally healthy patients requiring single implant-restoration, in either mandible or maxilla, with cement-retained prosthetic restoration. Twelve months after prosthetic loading, MBL in relation to prosthetic abutment height (AH), calculated radiographically, was statistically analyzed.
SEM and profilometer analyses revealed no differences between the SDE-surfaces of either SDE- or H-implants. Transverse ridges and grooves characterized the machined portion of H-implants, clearly influencing the profilometer analysis. In 75 patients, 37 SDE and 38 H-implants were placed and all functioned completely after 12 months. In both SDE- and H-groups, MBL had a significant inverse relationship with AH, with greater intercept and negative slope for SDE-group and intersection of the 2 regression lines at AH = 2 mm.
A 100% survival rate was recorded for SDE- and H-implants placed in pristine bone of periodontally healthy patients; MBL was limited and similar in both SDE- and H-groups; the higher the prosthetic AH, the lesser the MBL around implants; H-implants could reduce bone loss most effectively with abutments lower than 2 mm, realistically exploitable on thin biotypes; SDE-implants could reduce bone loss most effectively with abutments greater than 2 mm, realistically exploitable on thick biotypes.
目前缺乏具有相同设计但不同表面的植入物的人体研究。
本研究旨在比较两种具有相同设计但不同表面的种植体的存活率和边缘骨吸收(MBL):全“喷砂酸蚀”(SDE)种植体和混合(H)种植体,其根尖为 SDE 表面,冠部为机械加工表面。
SDE 和 H 表面在 SEM 和轮廓仪下进行了分析。种植体被放置在下颌或上颌有部分缺牙且牙周健康的患者中,这些患者需要单个种植体修复,采用粘结固位修复体。在修复体负重 12 个月后,通过影像学计算与修复体基台高度(AH)的关系,对 MBL 进行统计学分析。
SEM 和轮廓仪分析显示,SDE 种植体的 SDE 表面和 H 种植体的 SDE 表面之间没有差异。横向脊和槽特征是 H 种植体机械加工部分的特点,明显影响轮廓仪分析。在 75 名患者中,共植入 37 个 SDE 种植体和 38 个 H 种植体,所有种植体在 12 个月后均完全正常工作。在 SDE 组和 H 组中,MBL 与 AH 呈显著负相关,SDE 组的截距和斜率更大,两条回归线的交点在 AH=2mm 处。
将 SDE 和 H 种植体植入牙周健康患者的原始骨中,记录到 100%的存活率;SDE 组和 H 组的 MBL 均有限且相似;种植体基台高度越高,种植体周围的 MBL 越少;当基台高度低于 2mm 时,H 种植体可有效减少骨量损失,在较薄的生物型上具有现实可操作性;当基台高度大于 2mm 时,SDE 种植体可有效减少骨量损失,在较厚的生物型上具有现实可操作性。