Suppr超能文献

在存在随机头部定位误差的锥形束计算机断层扫描合成头影测量片上进行下颌形态测量的重测信度。

Test-retest reliability of mandibular morphology measurements on cone-beam computed tomography-synthesized cephalograms with random head positioning errors.

作者信息

Lin Hsien-Shu, Chen Yunn-Jy, Lu Hsuan-Lun, Lu Tung-Wu, Chen Chien-Chih

机构信息

Department of Dentistry, School of Dentistry, National Taiwan University Hospital, Taipei, Taiwan, ROC.

Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, ROC.

出版信息

Biomed Eng Online. 2017 May 30;16(1):62. doi: 10.1186/s12938-017-0353-8.

Abstract

BACKGROUND

Cephalometric radiography has been used for orthodontic and surgical treatment planning and assessment, and for quantifying mandibular growth. However, it remains unclear how head positioning errors and the level of examiner experience affect the reliability of such morphometric measurements. The current study aimed to bridge the gap by determining the intra-, inter-rater, and inter-session reliability of measurements of mandibular morphology with random head positioning errors as measured by a junior and a senior dentist.

METHODS

Cone-beam computed tomography data of twelve mandibles were obtained with each rotated randomly away from the neutral position within the range of +3 and -3° along each of the anatomical axes to simulate six imaging trials. A synthetic cephalogram for each trial was obtained via a digitally reconstructed radiography (DRR) technique and eleven landmarks for twelve morphological parameters on the cephalogram were identified manually six times by a junior and a senior dentist. The procedure was repeated on another day within 5 days. Test-retest reliability was assessed in terms of an intra-class correlation coefficient (ICC) using a two-way mixed-effects model.

RESULTS

Good to very good intra-rater (senior: ICC > 0.92; junior: ICC > 0.78), inter-rater (ICC > 0.70 for most parameters) and inter-session reliability (senior: ICC > 0.84; junior: ICC > 0.62) were found. Bland & Altman plots of inter-rater comparisons show that there were systematical biases between the examiners on most parameters, except for the distance between Gonion and Pogonion.

CONCLUSIONS

The current results suggest that good to very good intra-rater, inter-rater and inter-session reliability can be achieved for most parameters with randomized head positioning errors; higher inter-session reliability can be achieved by more experienced examiners; and that long-term monitoring of mandibular growth based on cephalographic measurements should be made by the same more experienced examiner. The current DRR-based approach can be used to evaluate individual factors that affect the morphological measurements.

摘要

背景

头影测量X线摄影已用于正畸和外科治疗计划及评估,以及量化下颌骨生长。然而,头部定位误差和检查者经验水平如何影响此类形态测量的可靠性仍不清楚。本研究旨在通过确定初级和高级牙医测量下颌骨形态时随机头部定位误差的测量内部、测量者间和测量阶段间的可靠性来填补这一空白。

方法

获取12个下颌骨的锥形束计算机断层扫描数据,每个下颌骨沿每个解剖轴在+3°和-3°范围内随机偏离中立位置旋转,以模拟6次成像试验。通过数字重建放射摄影(DRR)技术获得每次试验的合成头影图,初级和高级牙医分别对该头影图上11个标志点的12个形态学参数进行6次手动识别。该过程在5天内的另一天重复进行。使用双向混合效应模型,根据组内相关系数(ICC)评估重测可靠性。

结果

发现测量内部(高级:ICC>0.92;初级:ICC>0.78)、测量者间(大多数参数ICC>0.70)和测量阶段间可靠性良好至非常好(高级:ICC>0.84;初级:ICC>0.62)。测量者间比较的Bland & Altman图显示,除下颌角点与颏前点之间的距离外,检查者在大多数参数上存在系统偏差。

结论

目前的结果表明,对于大多数存在随机头部定位误差的参数,测量内部、测量者间和测量阶段间可靠性良好至非常好;经验更丰富的检查者可实现更高的测量阶段间可靠性;基于头影测量的下颌骨生长长期监测应由同一位经验更丰富的检查者进行。目前基于DRR的方法可用于评估影响形态测量的个体因素。