Mauschitz Matthias M, Roth Felix, Holz Frank G, Breteler Monique M B, Finger Robert P
Department of Population Health Sciences, German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany
Augenklinik Roth GmbH, Bonn, Germany
Invest Ophthalmol Vis Sci. 2017 May 1;58(5):2804-2809. doi: 10.1167/iovs.17-21675.
To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements.
Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL).
RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity.
Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.
评估晶状体混浊对视网膜神经纤维层厚度(RNFLT)及布鲁赫膜开口(BMO)测量的影响。
选取了59例在两家专业眼科诊所接受择期常规白内障手术、无其他相关眼部病变的患者。在白内障手术前及术后1天,使用海德堡工程公司的Spectralis OCT,通过解剖定位系统(APS),在视盘不同偏心度(3.5、4.1和4.7 mm)下进行环形扫描,评估RNFLT、BMO面积及BMO最小边缘宽度(BMO-MRW)。基于Scheimpflug图像(Oculus Pentacam AXL),使用密度测定法对晶状体混浊进行量化。
白内障摘除术前和术后,RNFLT、BMO面积及BMO-MRW几乎相同。在整体评估、3.5-mm扫描的六个扇区内评估或在任何其他偏心度下评估时均如此。基线RNFLT与晶状体混浊无关。
与先前研究报告的结果相反,使用APS时,白内障手术后RNFLT保持不变。我们的结果表明,APS可能有助于进行更精确的光谱域光学相干测量,将白内障对我们队列中RNFLT和BMO评估的影响降至最低。