Suppr超能文献

碳标记物的胃内及胃后处理使得碳呼吸试验成为一种不适用于健康成年人脂质乳剂胃排空测量的方法。

Gastric and Postgastric Processing of C Markers Renders the C Breath Test an Inappropriate Measurement Method for the Gastric Emptying of Lipid Emulsions in Healthy Adults.

作者信息

Parker Helen L, Liu Dian, Curcic Jelena, Ebert Marc-Olivier, Schwizer Werner, Fried Michael, Steingoetter Andreas

机构信息

Division of Gastroenterology and Hepatology, University Hospital Zurich, Zurich, Switzerland.

School of Medicine, Pharmacy, and Health, Durham University, Stockton-on-Tees, United Kingdom; and.

出版信息

J Nutr. 2017 Jul;147(7):1258-1266. doi: 10.3945/jn.117.248765. Epub 2017 May 31.

Abstract

Breath tests (BTs) present an alternative gastric-emptying (GE) measure. However, their efficacy in the measurement of the GE rate of lipid emulsions (LEs) is unknown. The objective of this work was to investigate the validity of C BTs as a measure of fat GE rate in LEs. The lipophilic C octanoate (OCC) BT marker was investigated for fat GE with the hydrophilic C sodium acetate (ACC) and the triglyceride C trioctanoin (TCC) markers as comparators. Data from 2 randomized studies were combined [50 healthy participants; 25 men, mean ± SD age: 23 ± 2.8 y; mean ± SD body mass index (in kg/m): 22.4 ± 1.7]. Each participant was given either an acid-stable LE (LE1) or an acid-unstable LE (LE4) at each visit. Twenty-three participants underwent simultaneous MRI. The effect of LEs on CO excretion profiles was determined. The BT half-emptying times (BT T) were validated with the MRI half-emptying time of the ingested fat volume (MRI T). The effect of LEs on CO excretion depended on the properties of the C marker. T for OCC was shorter by 98 min for LE1 than for LE4 ( < 0.001). Other markers showed either no LE dependency or a longer T for LE1 than for LE4. No difference in T between OCC and ACC was detected in LE1. In LE4, the T was longer by 154 min ( 0.0001). There was some concordance between MRI T and OCC BT T for LE1 ( = 0.7). No other marker showed any concordance with fat GE. C-Nuclear magnetic resonance in vitro findings were compatible with changes in the kinetics of phase transfer of OCC dependent on its protonation state. The structure of fat present in the stomach affects CO excretion. The chemical properties of the C marker and their gastric and postgastric interaction with fat renders CO excretion an inappropriate measure of LE emptying in healthy adults. This trial was registered at clinicaltrials.gov as NCT02226029 and NCT02602158.

摘要

呼气试验(BTs)是一种替代的胃排空(GE)测量方法。然而,其在测量脂质乳剂(LEs)的胃排空率方面的有效性尚不清楚。这项工作的目的是研究碳呼气试验(C BTs)作为LEs中脂肪胃排空率测量方法的有效性。以亲水性碳醋酸钠(ACC)和甘油三酯碳三辛酸甘油酯(TCC)标记物作为对照,研究了亲脂性碳辛酸(OCC)BT标记物用于脂肪胃排空的情况。合并了两项随机研究的数据[50名健康参与者;25名男性,平均±标准差年龄:23±2.8岁;平均±标准差体重指数(kg/m²):22.4±1.7]。每次就诊时,给每位参与者服用一种酸稳定的LE(LE1)或一种酸不稳定的LE(LE4)。23名参与者同时接受了磁共振成像(MRI)检查。确定了LEs对二氧化碳(CO)排泄曲线的影响。用摄入脂肪量的MRI半排空时间(MRI T)验证了BT半排空时间(BT T)。LEs对CO排泄的影响取决于碳标记物的性质。LE1的OCC的T比LE4短98分钟(P<0.001)。其他标记物要么没有LE依赖性,要么LE1的T比LE4长。在LE1中,未检测到OCC和ACC之间的T有差异。在LE4中,T长154分钟(P=0.0001)。LE1的MRI T和OCC BT T之间存在一定的一致性(r=0.7)。没有其他标记物与脂肪胃排空显示出任何一致性。体外碳核磁共振结果与OCC相转移动力学随其质子化状态的变化相一致。胃中存在的脂肪结构会影响CO排泄。碳标记物的化学性质及其与脂肪在胃内和胃后的相互作用使得CO排泄不是健康成年人中LE排空的合适测量方法。该试验在clinicaltrials.gov上注册为NCT02226029和NCT02602158。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验