SENSIMED Triggerfish在白内障超声乳化吸出联合ExPRESS手术术后随访中的疗效

Efficacy of the SENSIMED Triggerfish in the postoperative follow-up of PHACO-ExPRESS combined surgery.

作者信息

Osorio-Alayo V, Pérez-Torregrosa V T, Clemente-Tomás R, Olate-Pérez Á, Cerdà-Ibáñez M, Gargallo-Benedicto A, Barreiro-Rego A, Duch-Samper A

机构信息

Servicio de Oftalmología, Hospital Clínico Universitario de Valencia, Valencia, España.

Servicio de Oftalmología, Hospital Clínico Universitario de Valencia, Valencia, España.

出版信息

Arch Soc Esp Oftalmol. 2017 Aug;92(8):372-378. doi: 10.1016/j.oftal.2017.04.003. Epub 2017 May 31.

Abstract

OBJECTIVE

To determine the usefulness of the SENSIMED Triggerfish system in the postoperative control of combined phacoemulsification and ExPRESS implant (PHACO-ExPRESS) surgery in patients with cataract and chronic open angle glaucoma (COAG) during a 2 months follow-up.

METHODS

A prospective study conducted on 15 eyes that were subjected to PHACO-ExPRESS combined surgery. Using the SENSIMED Triggerfish system, two records of the circadian patterns of intraocular pressure (IOP) were performed, one before and one after surgery. A record was made of the best corrected visual acuity (BCVA), comorbidities, previous IOP, and 7-30-60 days after surgery, as well as any hypotensive drugs and complications.

RESULTS

The final sample was 12 eyes. The mean pre-operative BCVA (log MAR chart) before surgery was 0.5±0.2, and after surgery 0.14±0.1 (P=.02). The previous IOP was 18.7±3.8mmHg with 2.9±0.7 drugs. The mean IOP at 7, 30, and 60 days after surgery decreased to 13±4.1mmHg (P=.002), 13.5±2mmHg (P=.001), and 13.9±2.5mmHg (P=.001), respectively. The amplitudes of the circadian curves changed significantly after surgery (P=.007). The mean values between daytime and night-time periods decreased significantly from 146.8±80.9 mVeq and 61.2±92.mVeq before surgery to 36.4±36 mVeq (P=.000), and -23,2±47.6mVeq (P=.014) after surgery, respectively. There were complications in one patient.

CONCLUSIONS

The SENSIMED Triggerfish monitoring system showed changes in the curves of the circadian patterns, as well as decreased mean amplitudes after the combined PHACO-ExPRESS technique, suggesting that it may become a useful tool for postoperative follow-up of COAG.

摘要

目的

确定SENSIMED Triggerfish系统在白内障合并慢性开角型青光眼(COAG)患者行白内障超声乳化吸除联合ExPRESS植入术(PHACO-ExPRESS)后2个月随访期间对眼压控制的有效性。

方法

对15只接受PHACO-ExPRESS联合手术的眼睛进行前瞻性研究。使用SENSIMED Triggerfish系统,在手术前后各进行一次眼压昼夜模式记录。记录最佳矫正视力(BCVA)、合并症、术前眼压,以及术后7、30、60天的情况,还有任何降压药物和并发症。

结果

最终样本为12只眼睛。术前平均BCVA(对数最小分辨角视力表)为0.5±0.2,术后为0.14±0.1(P = 0.02)。术前眼压为18.7±3.8mmHg,使用2.9±0.7种药物。术后7天、30天和60天的平均眼压分别降至13±4.1mmHg(P = 0.002)、13.5±2mmHg(P = 0.001)和13.9±2.5mmHg(P = 0.001)。术后昼夜曲线的振幅有显著变化(P = 0.007)。白天和夜间的平均值从术前的146.8±80.9 mVeq和61.2±92.mVeq分别显著降至术后的36.4±36 mVeq(P = 0.000)和-23.2±47.6mVeq(P = 0.014)。有1例患者出现并发症。

结论

SENSIMED Triggerfish监测系统显示,在PHACO-ExPRESS联合技术后,昼夜模式曲线发生了变化,且平均振幅降低,这表明它可能成为COAG术后随访的有用工具。