Ophthalmology. 2020 Nov;127(11):1487-1497. doi: 10.1016/j.ophtha.2020.05.010. Epub 2020 May 15.
To investigate 24-hour nyctohemeral intraocular pressure (IOP)-related patterns with contact lens sensors (CLSs) in eyes with primary open-angle glaucoma (POAG) with normal baseline IOP (i.e., normal-tension glaucoma [NTG]) and healthy controls.
Prospective, case-control study.
Thirty eyes of 30 patients with NTG, who had had a wash-out period for their IOP-lowering treatment, and 20 eyes of 20 healthy volunteer subjects.
Patients and subjects were hospitalized for the purposes of 24-hour CLS (SENSIMED Triggerfish; Sensimed AG, Lausanne, Switzerland) measurement. The IOP-related patterns during wake and sleep times over the course of the 24 hours were compared between the 2 groups. The 24-hour ambulatory blood pressure and posture were monitored simultaneously. A generalized linear model was used to find the factors associated with NTG.
The IOP-related patterns, including mean and standard deviation (SD) of measurements, amplitude of cosine-fit curve, acrophase (signal peak), and bathyphase (signal trough) values (millivolt equivalents [mVEq]).
The SDs of the 24-hour CLS measurements were significantly greater in NTG eyes than in healthy controls (112.51±26.90 vs. 85.18±29.61 mVEq, P = 0.002). The amplitudes of cosine-fit curve (141.88±39.96 vs. 106.08±41.49 mVEq, P = 0.004) and acrophase values (277.74±129.80 vs. 190.58±127.88 mVEq, P = 0.024), mostly measured during nocturnal period, were significantly greater in NTG eyes than in healthy controls. The NTG subjects slept longer in the lateral decubitus posture than the healthy controls (199.1±137.8 vs. 113.2±86.2 minutes, P = 0.009). In the multivariable generalized linear model, the greater amplitude of cosine-fit curve (β = 0.218, P = 0.012) and greater time of decubitus posture during sleep (β = 0.180, P = 0.004) were found to be significantly associated with NTG.
Continuous monitoring of 24-hour IOP-related values with CLS can be useful for assessment of glaucoma risk, especially for patients with NTG whose IOP appears to be in the normal range. Fluctuation of 24-hour IOP-related values and posture during sleep time might be associated with NTG.
利用接触镜传感器(CLS)研究原发性开角型青光眼(POAG)伴正常基线眼压(即正常眼压性青光眼[NTG])和健康对照者的 24 小时昼夜眼压(IOP)相关模式。
前瞻性病例对照研究。
30 例 NTG 患者的 30 只眼,这些患者已经过了降眼压治疗的洗脱期,以及 20 例健康志愿者的 20 只眼。
患者和受试者住院进行 24 小时 CLS(SENSIMED Triggerfish;Sensimed AG,洛桑,瑞士)测量。比较两组在 24 小时内清醒和睡眠期间的 IOP 相关模式。同时监测 24 小时动态血压和体位。使用广义线性模型寻找与 NTG 相关的因素。
包括测量的平均值和标准差(SD)、余弦拟合曲线的幅度、信号峰值(acrophase)和信号谷值(bathyphase)值(毫伏等效值[mVEq])。
NTG 眼的 24 小时 CLS 测量的 SD 明显大于健康对照组(112.51±26.90 对 85.18±29.61 mVEq,P=0.002)。余弦拟合曲线的幅度(141.88±39.96 对 106.08±41.49 mVEq,P=0.004)和信号峰值值(277.74±129.80 对 190.58±127.88 mVEq,P=0.024)在夜间主要测量时,NTG 眼明显大于健康对照组。NTG 受试者侧卧睡眠时间长于健康对照组(199.1±137.8 对 113.2±86.2 分钟,P=0.009)。在多变量广义线性模型中,发现余弦拟合曲线幅度较大(β=0.218,P=0.012)和睡眠期间侧卧时间较长(β=0.180,P=0.004)与 NTG 显著相关。
CLS 对 24 小时 IOP 相关值的连续监测对于评估青光眼风险可能是有用的,特别是对于眼压似乎处于正常范围的 NTG 患者。24 小时 IOP 相关值和睡眠时间体位的波动可能与 NTG 有关。