Bongers Suzan, Slottje Pauline, Kromhout Hans
Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands.
Department of General Practice and Elderly Car, VU University Medical Centre, Amsterdam, The Netherlands.
Occup Environ Med. 2017 Nov;74(11):776-784. doi: 10.1136/oemed-2016-103750. Epub 2017 Jun 10.
To study the effects of repeated exposure to MRI-related acoustic noise during image acquisition procedures (scans) on hearing.
A retrospective occupational cohort study was performed among workers of an MRI manufacturing facility (n=474). Longitudinal audiometry data from the facility's medical surveillance scheme collected from 1973 to 2010 were analysed by studying the association of cumulative exposure to MRI-related acoustic noise from voluntary (multiple) MRI scans and the hearing threshold of the volunteer.
Repeated acoustic noise exposure during volunteer MRI scans was found to be associated with a small exposure-dependent increased rate change of hearing threshold level (dB/year), but the association was only found related to the number of voluntary MRI scans and not to modelled cumulative noise exposure (dB*hour) based on MRI-system type. The increased rate change of hearing threshold level was found to be statistically significant for the frequencies 500, 1000, 2000, 3000 and 4000 Hz in the right ear.
From our longitudinal cohort study, it appeared that exposure to noise from voluntarily MRI scans may have resulted in a slight amount of hearing loss. Mandatory use of hearing protection might have prevented more severe hearing loss. Lack of consistency in findings between the left and right ears and between the two exposure measures prohibits definitive conclusions. Further research that addresses the study's methodological limitations is warranted to corroborate our findings.
研究在图像采集程序(扫描)期间反复暴露于与磁共振成像(MRI)相关的噪声对听力的影响。
对一家MRI制造工厂的工人(n = 474)进行了一项回顾性职业队列研究。通过研究自愿(多次)MRI扫描导致的与MRI相关的噪声累积暴露量与志愿者听力阈值之间的关联,分析了该工厂1973年至2010年医疗监测计划收集的纵向听力测定数据。
发现在志愿者MRI扫描期间反复暴露于声学噪声与听力阈值水平(dB/年)的小幅度暴露依赖性增加率变化有关,但该关联仅与自愿MRI扫描的次数有关,而与基于MRI系统类型的模拟累积噪声暴露量(dB*小时)无关。发现右耳在500、1000、2000、3000和4000Hz频率处听力阈值水平的增加率变化具有统计学意义。
从我们的纵向队列研究来看,似乎自愿进行MRI扫描时暴露于噪声可能导致了轻微的听力损失。强制使用听力保护措施可能会预防更严重的听力损失。左右耳之间以及两种暴露测量方法之间的结果缺乏一致性,因此无法得出明确结论。有必要进行进一步的研究以解决该研究的方法学局限性,从而证实我们的发现。