Abstract

PURPOSE

To determine the retention rate (RR) for neophyte patients fitted with contact lenses (CLs) and to identify factors associated with retention and dropout.

METHOD

This multisite, sponsor-masked registry study evaluated the 1-year status of neophyte CL wearers fitted in a representative range of UK practices. A total of 26 UK investigational sites each recruited up to 89 neophyte patients. The participants were requested to complete surveys at 1 month (±1 week from date of fitting), 3 months (±2 weeks), and 12 months (±3 weeks) online or through phone. Participants were contacted by email (or phone) and invited to complete an online survey that asked a range of questions regarding their CL wearing experience.

RESULTS

Of the 531 participants recruited, 65.3% (347/531) responded to at least one follow-up survey and 42.3% (225/531) responded to all three surveys. One in four patients showed discontinued CL wear by 12 months. Based on evaluable subjects at 12 months, the RR was 77.6% (194/250, 95% confidence interval: 72.0-82.3). The most common reason for discontinuation was problems with vision (41%), followed by discomfort (36%) and handling problems (25%). The factors affecting first-year RRs: sex, spherical refraction, lens usage (full time or part time), and supply method (collected or posted).

CONCLUSIONS

In this prospective study, the first-year RR for neophyte CL wearers was 77.6%. This was consistent with that noted in a retrospective study: 74.0%. As with the previous study, the commonly cited reason for discontinuation was visual problems.

摘要

目的

确定佩戴隐形眼镜(CL)的新手患者的留存率(RR),并识别与留存和退出相关的因素。

方法

这项多中心、申办方设盲的注册研究评估了在英国一系列具有代表性的医疗机构中配镜的新手CL佩戴者的1年情况。英国共有26个研究站点,每个站点招募了多达89名新手患者。要求参与者在1个月(配镜日期±1周)、3个月(±2周)和12个月(±3周)通过在线或电话方式完成调查。通过电子邮件(或电话)联系参与者,邀请他们完成一项在线调查,该调查询问了一系列关于他们CL佩戴体验的问题。

结果

在招募的531名参与者中,65.3%(347/531)至少回复了一项随访调查,42.3%(225/531)回复了所有三项调查。四分之一的患者在12个月时停止佩戴CL。基于12个月时可评估的受试者,RR为77.6%(194/250,95%置信区间:72.0 - 82.3)。最常见的停止佩戴原因是视力问题(41%),其次是不适(36%)和操作问题(25%)。影响第一年RR的因素有:性别、球镜度数、镜片使用方式(全职或兼职)以及供应方式(自取或邮寄)。

结论

在这项前瞻性研究中,新手CL佩戴者的第一年RR为77.6%。这与一项回顾性研究中记录的74.0%一致。与之前的研究一样,常见的停止佩戴原因是视力问题。