一种用于评估乳房切除术后皮瓣血流的新型非接触式扩散相关光谱装置:一项针对接受假体植入重建患者的前瞻性研究。

A Novel Noncontact Diffuse Correlation Spectroscopy Device for Assessing Blood Flow in Mastectomy Skin Flaps: A Prospective Study in Patients Undergoing Prosthesis-Based Reconstruction.

作者信息

Agochukwu Nneamaka B, Huang Chong, Zhao Mingjun, Bahrani Ahmed A, Chen Li, McGrath Patrick, Yu Guoqiang, Wong Lesley

机构信息

Lexington, Ky.

From the Division of Plastic Surgery, the Department of Biomedical Engineering, the Department of Biostatistics, the Markey Cancer Center, Biostatistics Shared Resource Facility, and the Division of General Surgery, University of Kentucky.

出版信息

Plast Reconstr Surg. 2017 Jul;140(1):26-31. doi: 10.1097/PRS.0000000000003415.

Abstract

UNLABELLED

A new advanced technology, noncontact diffuse correlation spectroscopy, has been recently developed for the measurement of tissue blood flow through analyzing the motions of red blood cells in deep tissues. This technology is portable, inexpensive, and noninvasive, and can measure up to 1.5-cm tissue depth. In this prospective study, the authors aimed to explore the use of this novel device in the prediction of mastectomy skin flap necrosis. The noncontact diffuse correlation spectroscopy device was used to measure mastectomy skin flap flow in patients undergoing mastectomy and immediate implant-based breast reconstruction before and immediately after mastectomy, and after placement of the prosthesis. Patients were tracked for the development of complications, including skin necrosis and the need for further surgery. Nineteen patients were enrolled in the study. Four patients (21 percent) developed skin necrosis, one of which required additional surgery. The difference in relative blood flow levels immediately after mastectomy in patients with or without necrosis was statistically significant, with values of 0.27 ± 0.11 and 0.66 ± 0.22, respectively (p = 0.0005). Relative blood flow measurements immediately after mastectomy show a significant high accuracy in prediction of skin flap necrosis, with an area under the receiver operating characteristic curve of 0.95 (95 percent confidence interval, 0.81 to 1). The noncontact diffuse correlation spectroscopy device is a promising tool that provides objective information regarding mastectomy skin flap viability intraoperatively, allowing surgeons early identification of those compromised and ischemic flaps with the hope of potentially salvaging them.

CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.

摘要

未标注

一种新的先进技术,非接触式扩散相关光谱技术,最近已被开发用于通过分析深部组织中红细胞的运动来测量组织血流。该技术便携、廉价且无创,可测量达1.5厘米的组织深度。在这项前瞻性研究中,作者旨在探索使用这种新型设备预测乳房切除术后皮瓣坏死。非接触式扩散相关光谱设备用于测量接受乳房切除术并立即进行基于植入物的乳房重建的患者在乳房切除术前、乳房切除术后即刻以及植入假体后的乳房切除皮瓣血流。对患者进行并发症发生情况的跟踪,包括皮肤坏死以及是否需要进一步手术。19名患者纳入研究。4名患者(21%)发生皮肤坏死,其中1例需要额外手术。乳房切除术后即刻,有或无坏死患者的相对血流水平差异具有统计学意义,分别为0.27±0.11和0.66±0.22(p = 0.0005)。乳房切除术后即刻的相对血流测量在预测皮瓣坏死方面具有显著的高准确性,受试者工作特征曲线下面积为0.95(95%置信区间,0.81至1)。非接触式扩散相关光谱设备是一种有前景的工具,可在术中提供有关乳房切除皮瓣存活能力的客观信息,使外科医生能够早期识别那些受损和缺血的皮瓣,有望对其进行挽救。

临床问题/证据水平:诊断性,IV级。