Suppr超能文献

在相同情况下,使用常规种植体和短种植体以及联冠和非联冠修复体时下颌骨后部骨应力的有限元分析

Finite Element Analysis of Bone Stress in the Posterior Mandible Using Regular and Short Implants, in the Same Context, with Splinted and Nonsplinted Prostheses.

作者信息

Toniollo Marcelo Bighetti, Macedo Ana Paula, Pupim Denise, Zaparolli Danilo, da Gloria Chiarello de Mattos Maria

出版信息

Int J Oral Maxillofac Implants. 2017 Jul/Aug;32(4):e199-e206. doi: 10.11607/jomi.5611.

Abstract

PURPOSE

The aim of this study was to compare the bone stress generated by rehabilitation using regular and short-length Morse taper implants (11 and 5 mm, respectively) in the same context and allied with splinted (SP) and nonsplinted (NSP) prostheses in the posterior area of the mandible using finite element analysis.

MATERIALS AND METHODS

Three-dimensional geometric models using regular implants (Ø4 × 11 mm) and short implants (Ø4 × 5 mm) were simulated with a left posterior mandible that had the first premolar tooth and all teeth posterior to that premolar removed. The four experimental groups were as follows: Group 1 NSP (two regular implants and one short implant rehabilitated with nonsplinted prostheses), Group 1 SP (two regular implants and one short implant rehabilitated with splinted prostheses), Group 2 NSP (one regular implant and two short implants rehabilitated with nonsplinted prostheses), and Group 2 SP (one regular implant and two short implants rehabilitated with splinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using the ANSYS Workbench software, version 10.0.

RESULTS

The splinted prostheses decreased the stress to the surrounding bone of short implants. Moreover, they also decreased the stress on the surrounding bone adjacent to the tooth. However, the splinted prostheses generated higher stress in the coverage of the surrounding bone for regular intermediate implants and prominently in the bone at the implant cervical region, at the edge crest, compared with the individualized groups.

CONCLUSION

The benefits in the use of splinted prostheses are notable for the preservation of the bone surrounding the short implants and tooth; however, it is necessary to evaluate each clinical situation because, in this context, the regular implants are at higher stress than the individualized implants.

摘要

目的

本研究旨在通过有限元分析,比较在下颌骨后部相同情况下,使用常规长度和短长度莫氏锥度种植体(分别为11毫米和5毫米)进行修复,并联合使用夹板式(SP)和非夹板式(NSP)假体时所产生的骨应力。

材料与方法

使用常规种植体(直径4×11毫米)和短种植体(直径4×5毫米)的三维几何模型,模拟拔除左侧下颌骨第一前磨牙及该前磨牙后方所有牙齿后的情况。四个实验组如下:第1组NSP(两个常规种植体和一个短种植体,采用非夹板式假体修复),第1组SP(两个常规种植体和一个短种植体,采用夹板式假体修复),第2组NSP(一个常规种植体和两个短种植体,采用非夹板式假体修复),第2组SP(一个常规种植体和两个短种植体,采用夹板式假体修复)。模拟磨牙(365牛)和前磨牙(200牛)上的斜向力。使用ANSYS Workbench 10.0版软件对骨内最小主应力进行定性和定量分析。

结果

夹板式假体降低了短种植体周围骨的应力。此外,它们还降低了牙齿相邻周围骨的应力。然而,与个体化组相比,夹板式假体在常规中等长度种植体周围骨覆盖区域,尤其是种植体颈部区域边缘嵴处的骨中产生了更高的应力。

结论

使用夹板式假体对保留短种植体和牙齿周围的骨具有显著益处;然而,有必要评估每种临床情况,因为在这种情况下,常规种植体比个体化种植体承受的应力更高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验