Yoshida Masahito, Goto Hideyuki, Takenaga Tetsuya, Tsuchiya Atsushi, Sugimoto Katsumasa, Musahl Volker, Fu Freddie, Otsuka Takanobu
Department of Orthopaedic Surgery, Nagoya City University Graduate School of Medical Science, Nagoya, Japan; Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA.
Department of Orthopaedic Surgery, Nagoya City University Graduate School of Medical Science, Nagoya, Japan.
J Shoulder Elbow Surg. 2017 Oct;26(10):1803-1809. doi: 10.1016/j.jse.2017.05.025. Epub 2017 Jul 20.
The anterior oblique bundle (AOL) of the ulnar collateral ligament (UCL) is composed of anterior and posterior bands. This study evaluated the anatomy of the anterior and posterior bands in the AOL of the UCL for their separate visualization with ultrasound (US).
We dissected 18 cadaveric elbow joints and recorded the direction of each band from the lateral view to determine the proper position for the US transducer. To determine the proper inclination of the transducer, we measured the inclinations of each band at the proximal and distal insertions from the transverse view. A paired t test was used for comparisons between both bands. Values of P < .05 were considered statistically significant.
The mean angles of the directions in the anterior and posterior bands were 10° ± 4° and 24° ± 9°, respectively. At the medial epicondyle, the mean inclination angles of both bands were 61° ± 5° and 67° ± 5°, respectively. At the sublime tubercle, the mean inclination angles of both bands were 14° ± 7° and 44° ± 9°, respectively. The inclination angles at the proximal ulna and the directions in both bands were significantly different (P < .001).
This study shows that the directions of both bands and inclination angles of the bony attachments in both bands can assist with correct placement of the US transducer and allow for separate visualization of each band.
尺侧副韧带(UCL)的前斜束(AOL)由前束和后束组成。本研究评估了UCL的AOL中前束和后束的解剖结构,以便通过超声(US)对其进行单独可视化。
我们解剖了18个尸体肘关节,并从侧面记录了每条束的方向,以确定超声换能器的正确位置。为了确定换能器的正确倾斜度,我们从横断面测量了每条束在近端和远端附着处的倾斜度。采用配对t检验对两条束进行比较。P < 0.05的值被认为具有统计学意义。
前束和后束方向的平均角度分别为10°±4°和24°±9°。在内上髁处,两条束的平均倾斜角度分别为61°±5°和67°±5°。在小结节处,两条束的平均倾斜角度分别为14°±7°和44°±9°。尺骨近端的倾斜角度和两条束的方向有显著差异(P < 0.001)。
本研究表明,两条束的方向以及两条束中骨附着处的倾斜角度有助于超声换能器的正确放置,并能对每条束进行单独可视化。