Suppr超能文献

一种用于测量年轻人腰椎躯干刚度的新型滚动式机械压痕装置的舒适性和安全性。

The comfort and safety of a novel rolling mechanical indentation device for the measurement of lumbar trunk stiffness in young adults.

作者信息

Brown Benjamin T, Blacke Alexandra, Carroll Vanessa, Graham Petra L, Kawchuk Greg, Downie Aron, Swain Michael

机构信息

Department of Chiropractic, Macquarie University, Balaclava Rd, North Ryde, NSW 2109 Australia.

Department of Statistics, Macquarie University, Balaclava Rd, North Ryde, 2109 NSW Australia.

出版信息

Chiropr Man Therap. 2017 Aug 3;25:21. doi: 10.1186/s12998-017-0153-z. eCollection 2017.

Abstract

BACKGROUND

The measurement of Posterior-Anterior (P-A) spinal stiffness is a common component of the physical examination of patients presenting with spinal disorders. The aim of this assessment is to provoke pain and/or to determine the degree of resistance or compliance of these structures and the associated soft-tissues to loading. This information, combined with other patient-specific history and examination findings, is integrated into the clinical reasoning process and is used to guide treatment decisions. Unfortunately, there are inter-rater reliability and standardisation issues associated with the manual performance of this type of assessment. In an attempt to remedy these issues researchers have developed mechanical devices for the measurement of spinal stiffness. The aim of this research is to investigate the comfort and safety of a novel device for measuring P-A trunk stiffness in a sample of young adults.

METHODS

A sample of young adults from a general population was recruited in May 2016 from Sydney, Australia. Demographic, anthropometric and clinical variables were collected prior to participants undergoing a lumbar P-A trunk stiffness assessment involving a mechanical indentation device called the VerteTrack. The primary outcomes for the study were key feasibility items; overall assessment time, perceived comfort measured both during and after the procedure, and adverse events. Univariate ordinal logistic regression was used to identify key variables associated with a participant's subjective report of comfort both during and after the VerteTrack assessment.

RESULTS

Eighty four participants (35% female) with a median age of 23 years (IQR = 3) took part in the research. The mean assessment time for the Vertetrack assessment was 11.6 min (SD = 2.1). Increasing load ( < 0.001) and increasing number of days with lower back pain ( = 0.009) were associated with decreased comfort ratings during the procedure. The vast majority 63/84 (75%) of participants rated the overall assessment experience as comfortable. There were two minor, short-lived adverse events recorded leading to an adverse event rate of 2.4% (2/84).

CONCLUSIONS

The results of this study suggest that the VerteTrack device is well-tolerated and can be used safely and efficiently when measuring P-A stiffness of the lumbar trunk in young adults.

TRIAL REGISTRATION

Not applicable.

摘要

背景

测量脊柱前后(P-A)刚度是脊柱疾病患者体格检查的常见组成部分。该评估的目的是引发疼痛和/或确定这些结构以及相关软组织对负荷的抵抗程度或顺应性。这些信息与其他患者特定的病史和检查结果相结合,被整合到临床推理过程中,并用于指导治疗决策。不幸的是,这种类型的评估手动操作存在评分者间信度和标准化问题。为了解决这些问题,研究人员开发了用于测量脊柱刚度的机械设备。本研究的目的是调查一种用于测量年轻成年人样本中P-A躯干刚度的新型设备的舒适性和安全性。

方法

2016年5月从澳大利亚悉尼的普通人群中招募了一组年轻成年人样本。在参与者接受涉及一种名为VerteTrack的机械压痕装置的腰椎P-A躯干刚度评估之前,收集了人口统计学、人体测量学和临床变量。该研究的主要结果是关键可行性项目;总体评估时间、操作过程中和操作后测量的感知舒适度以及不良事件。使用单变量有序逻辑回归来确定与参与者在VerteTrack评估期间和之后的舒适度主观报告相关的关键变量。

结果

84名参与者(35%为女性)参与了研究,中位年龄为23岁(四分位间距=3)。VerteTrack评估的平均时间为11.6分钟(标准差=2.1)。负荷增加(<0.001)和下背痛天数增加(=0.009)与操作过程中舒适度评分降低相关。绝大多数84名参与者中的63名(75%)将总体评估体验评为舒适。记录到两起轻微、短暂的不良事件,不良事件发生率为2.4%(2/84)。

结论

本研究结果表明,VerteTrack设备耐受性良好,在测量年轻成年人腰椎P-A刚度时可以安全有效地使用。

试验注册

不适用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9d27/5541409/534632a25d3c/12998_2017_153_Fig1_HTML.jpg