Suppr超能文献

超声检查对无症状受检者腕管和正中神经测量的可靠性。

Reliability of measurement of the carpal tunnel and median nerve in asymptomatic subjects with ultrasound.

机构信息

Department of Physiatry and Nursery, Faculty of Heath Sciences, University of Zaragoza, C/Domingo Miral s/n, CP: 50009, Zaragoza, Spain.

Department of Physiatry and Nursery, Faculty of Heath Sciences, University of Zaragoza, C/Domingo Miral s/n, CP: 50009, Zaragoza, Spain.

出版信息

Musculoskelet Sci Pract. 2017 Dec;32:17-22. doi: 10.1016/j.msksp.2017.08.001. Epub 2017 Aug 5.

Abstract

BACKGROUND

Morphology of the carpal tunnel changes with varying wrist postures and compressive forces applied to the wrist. These changes may affect the morphology and pressure on the median nerve and could be used as part of the treatment of the carpal tunnel syndrome patients. Reliability of the ultrasonographic measurements of the median nerve has been widely studied. However, there is a lack of investigation regarding reliability of ultrasonographic measurements of the carpal tunnel.

OBJECTIVE

The purpose of this study was to assess intra-tester and inter-tester reliability of measurement of dimensions of the carpal tunnel and median nerve with ultrasound in asymptomatic volunteers.

DESIGN

A cross-sectional methodological study.

METHODS

Aspects measured were mediolateral and anteroposterior diameters, flattening ratio, circularity, perimeter and cross-section area of the carpal tunnel and median nerve.

RESULTS

Intra-tester reliability was excellent for the carpal tunnel (ICCs from 0.91 to 0.97) and for the median nerve (ICCs from 0.79 to 0.94) measurements. The flattening ratio of the median nerve showed good agreement (ICC = 0.68). Inter-tester reliability was excellent for the carpal tunnel measurements (ICCs from 0.76 to 0.95) and, for the cross sectional area, the perimeter and mediolateral diameter of the median nerve, the ICC values were 0.89, 0.84 and 0.81, respectively.

CONCLUSION

In the context of this study, ultrasound was a reliable instrument for measuring carpal tunnel and median nerve dimensions in asymptomatic subjects.

LEVEL OF EVIDENCE

1b.

摘要

背景

腕管的形态随腕部姿势和对腕部施加的压缩力的变化而变化。这些变化可能会影响正中神经的形态和压力,并可作为治疗腕管综合征患者的一部分。正中神经的超声测量的可靠性已得到广泛研究。然而,关于腕管超声测量的可靠性的研究还很少。

目的

本研究旨在评估超声测量无症状志愿者腕管和正中神经的尺寸的内部测试者和外部测试者之间的可靠性。

设计

一项横断面方法学研究。

方法

测量的方面包括腕管和正中神经的横径和前后径、扁平比、圆度、周长和横截面积。

结果

腕管(ICC 从 0.91 到 0.97)和正中神经(ICC 从 0.79 到 0.94)测量的内部测试者可靠性均为优秀。正中神经的扁平比具有良好的一致性(ICC=0.68)。腕管测量的外部测试者可靠性为优秀(ICC 从 0.76 到 0.95),而对于正中神经的横截面积、周长和横径,ICC 值分别为 0.89、0.84 和 0.81。

结论

在本研究背景下,超声是一种可靠的测量无症状受试者腕管和正中神经尺寸的仪器。

证据水平

1b。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验