Suppr超能文献

脐动脉插管导致的血管穿孔和假道形成:一例报告及文献综述

Vessel Perforation and False Tracking Resulting From Umbilical Artery Catheterization: A Case Report and Literature Review.

作者信息

Puvabanditsin Surasak, Zaldana Francisco, Raviola Joseph, Suell Jeffrey, Hussein Karen, Walzer Lauren, Mehta Rajeev

机构信息

1 Department of Pediatrics, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA.

2 Department of Pathology, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA.

出版信息

Pediatr Dev Pathol. 2017 Sep-Oct;20(5):426-431. doi: 10.1177/1093526616686454. Epub 2017 Jan 26.

Abstract

We report an extremely low-birth-weight neonate who developed umbilical artery perforation and false tracking. There was no life-threatening event relating to the complication. Diagnosis was made at postmortem examination. Little information exists regarding the anatomic and vascular effects of umbilical artery catheterization placement in newborns. We report a new complication of umbilical artery catheterization. We raise the awareness regarding the potential life threat due to this rare but very serious complication.

摘要

我们报告了一名极低出生体重的新生儿,该患儿发生了脐动脉穿孔和假通道形成。未出现与该并发症相关的危及生命的情况。诊断是在尸检时做出的。关于新生儿脐动脉置管的解剖学和血管影响的信息很少。我们报告了脐动脉置管的一种新并发症。我们提高了对这种罕见但非常严重的并发症可能危及生命的认识。